background image

page 16

MAC Filter

MAC Filter can set a registered MAC address to link to the matrix 10 MAC address can be 
used. After MAC address are entered select Enable and select Apply to save settings. Press 
Back to return to advanced page.

Scene

Save

:    

Save 10 sets of channel settings

Load

:    

Reload 1 of the channel settings

Update

:  

Refresh the status of load

Back

:    

Return to Advanced page

Summary of Contents for ELE9096

Page 1: ...4K x 2K HDMI 10x10 Matrix Switch ELE9096 USER MANUAL ...

Page 2: ...ontrol Android IOS App Control IR remote control RS 232 and the front panel 1 1 FEATURES 1 Connect up to 10 HDMI sources to 10 x HDMI display monitors 2 HDMI 1 4 with 3D HDCP DVI Compliant 3 High definition video up to 4K2K 24 25 30Hz 8bits 1080p 60Hz 12bits 4 Audio supports up to LPCM 7 1 192KHz Dolby TrueHD DTS HD MA 5 Easy to use front panel control of switching or using the included remote con...

Page 3: ...2 1 PANEL VIEW page 2 2 0 FEATURE SETUP DIAGRAM BD TV TV HDMI HDMI RS232 PC ELE9096 Set top Box Media Player Projector Home Theater Game Console ...

Page 4: ...on POWER Power on standby UP Up DOWN Down LEFT Left RIGHT Right ENTER Select confirm key MENU Back to main menu channel setting EDID Copy EDID LOCK Button lock ALL Set selected input channel to all output When pressing ALL the second line of the panel will show IN and the flashing select the input 1 10 then press ENTER OFF Turn off selected output could be 1 10 or ALL When pressing OFF the second ...

Page 5: ...button the IN line of LCM will blink press ALL or OUTPUT 1 10 to select which port to turn off EDID Press EDID button it will show From OUTPUT at second line of LCM and the channel number will blink press OUTPUT 1 10 to select which port to copy EDID Lock Press LOCK till LOCK LED on then the panel button and IR remote control of MATRIX will be locked Press LOCK till LOCK LED off to unlock When the...

Page 6: ...ting screen after 10 seconds press the MENU key to enter the main menu Operation 1 Press UP or DOWN key to move to select an item for setting and press ENTER key to enter into subpage 2 In MENU you could use key 1 6 of IR remote control to select the functions 3 When the selected sub page setting is completed press the MENU button to return to the main page Main Menu Options 1 Switch 2 Scene 3 Eth...

Page 7: ... sets of channel setting to fast reload for different application Load Reload saved scene press UP or DOWN to select the number of setting ENTER to load At main screen you could use IR01 remote button A for quick load function button 1 0 to select port number to load Save Save current channel setting press UP or DOWN to select the number and ENTER to save At main screen you could use IR01 remote b...

Page 8: ... will flash then press the UP or DOWN button to change the numbers Press ENTER press LEFT or RIGHT to move to another location the move to a position number will flash press ENTER to complete the setting Gateway 192 168 0 1 Gateway Default 192 168 0 1 This function can setup the MATRIX host intranet Gateway press ENTER the left most number of second row will flash then press the UP or DOWN button ...

Page 9: ...lt Auto This function will setup the MATRIX host intranet Media Type press ENTER the second row will flash then press the UP or DOWN button to select AUTO 10MHalf 10MFull 100MHalf 100MFull then press ENTER to complete the setting Media Type Auto MAC Filter Default Disable MAC Filter can be setup with a registered MAC Address in order to connect the MATRIX host Web UI MAC Address required by the We...

Page 10: ...ode This mode supports video resolution 480p 720p 1080i p at 24 50 60Hz and supports 1080P LPCM two channel audio and 5 1 channel After entering the BUILD IN MODE menu press UP or DOWN key to select 1080P LPCM 2CH or 1080P LPCM 5 1CH then press ENTER to confirm setting For 4K2K resolution you have to copy the EDID from your 4K2K monitor 1080P LPCM 2CH 1080P LPCM 5 1CH BUILD IN MODE COPY MODE I EDI...

Page 11: ...resolution TV EDID Otherwise it may cause no picture if the TV resolution is not able to support higher resolutions After entering COPY MODE menu press UP or DOWN button to select the OUTPUT 1 10 and press ENTER then press UP or DOWN button to select the INPUT 1 to 10 or ALL and press ENTER to confirm Only the connected output will be shown in OUTPUT list COPY MODE From OUTPUT 1 COPY MODE From INP...

Page 12: ...sents the lowest resolution This EDID is then transmitted to all sources E g if there is a monitor 1080p and a monitor 720p the matrix transmits to the sources the EDID of the 720p monitor PC EDID Mode In this mode you can upload an EDID file from RS232 or RJ45 port of PC to MATRIX please refer user manual of EDID Loader ...

Page 13: ...hen Press UP or DOWN button to select the number and then press ENTER to confirm When finish MATRIX IR ID setting MATRIX remote control IR01 must also set the same ID in order to operation in normal Remote IR ID setting mode Press and hold the POWER button then press the number button which can be set from 0 to 9 total 10 groups See 5 1 These settings on IR01 remote control have to be done the fir...

Page 14: ...mber key to save Remote Control Buttons Symbol Function ON Standby same as matrix Left same as matrix Right same as matrix Up same as matrix Down same as matrix Confirm same as matrix Menu same as matrix Quick key1 Quick key2 Quick key3 Quick key4 Quick key5 Quick key6 Quick key7 Quick key8 Quick key9 Quick key10 EDID same as matrix OFF same as matrix For example to connect output port 1 to input ...

Page 15: ... matrix power on and standby Output Display output 1 10 display names can be entered Input Display inputs 1 10 this field is a drop down menu Menu options include input 1 10 and OFF You can change the display name by using the aliases page Reload Get matrix host message Advanced Enter Advanced page Apply Save or execute settings All Port Set all outputs from input 1 10 all at once Switch Setting S...

Page 16: ... online setting auto reset time 1 255 minute will disconnect inactive users Scene Click to enter scene setup page MAC Filter Click to enter MAC Filter setup page Aliases Click to enter Aliases setup page Device Name Change device name Back Jump back to switch setting page Online Users are displayed max 4 on line Aliases Aliases page allows input and output names to be changed Press Apply to save c...

Page 17: ...10 MAC address can be used After MAC address are entered select Enable and select Apply to save settings Press Back to return to advanced page Scene Save Save 10 sets of channel settings Load Reload 1 of the channel settings Update Refresh the status of load Back Return to Advanced page ...

Page 18: ...nd set the IP subnet mask same as the matrix network segment Default IP address of 10 by 10 matrix is 192 168 0 10 Default subnet mask is 255 255 255 0 You could also set to DHCP mode please refer user manual There are two ways to get the IP address of matrix 1 Use APP function Scan Device to get the IP address 2 Use panel button or IR remote control by press MENU select to ETHERNET function and p...

Page 19: ...t the IP subnet mask to match the matrix network segment Default IP address of 10 by 10 matrix is 192 168 0 10 Default subnet mask is 255 255 255 0 You can also set to DHCP mode please refer user manual There are two ways to get the IP address of matrix 1 Use APP function Scan Device to get the IP address 2 Use panel button or IR remote control by press MENU select to ETHERNET function and press E...

Page 20: ... m MATRIX_ID p Set Matrix IR ID EDID_COPY n Copy EDID from TX n SAVE n Save setting to n LOAD n Load setting from n KEY y Panel button IR remote control Lock Unlock DHCP y DHCP client on off IP_ADDRESS x x x x Set Matrix IP address SUBNET_MASK x x x x Set Matrix subnet mask GATEWAY x x x x Set Matrix gateway MEDIA_TYPE z Network speed select MAC_FILTER y Mac filter on off STATUS Show connection st...

Page 21: ...pe A x 10 Video Output Interface HDMI Type A x 10 RS 232 Input Output Interface DB9 x 1 CONSOLE IR Receive Angle 45 degree IR Receive Distance 5M Power Adapter DC 12V 6 7A Power Consumption 5A Operating Temperature 0 to 55 c Storage Temperature 20 to 85 c Humidity up to 95 Dimension 19 x 7 8 x 3 5 Weight 8 6 lbs page 20 ...

Page 22: ......