Rigid Balanced Flue Connection Possibilities
Horizontal Wall Termination
Bidore 70/ Trisore 70
Diameter Concentric Flue: 200/130
Bidore 70 and Trisore 70 can be installed with a 90 degree bend direct to the fire.
Minimal vertical height “V” is the height of a 90 degree bend (20 cm)
Maximum height “V” whilst using a wall terminal: 3 meter
Horizontal possibilities:
0,5 meter vertical gives maximum horizontal 6 meter
Bidore 95/ Trisore 95
Diameter Concentric Flue: 200/130
Minimal vertical height “V” is 0,5 meter
Maximum vertical height “V” whilst using a wall terminal: 3 meter
Horizontal possibilities:
0,5 meter vertical gives maximum horizontal 2 meter
1,0 meter vertical gives maximum horizontal 6 meter
2.0 meter vertical gives maximum horizontal 12 meter!