S-LP

S-LP 133/62, S-LP 146/74, S-LP 160/62, S-LP 180/74

S-LP 200/74, S-LP 200/92, S-LP 215/92, S-LP 225/92, S-LP 250/104

S-LP 315/103

Elektror Edel-
stahl-Nieder-
druckventilatoren 
Betriebs- und
Montageanleitung

DE

Elektror Stain-
less-Steel Low 
Pressure Blowers 
Operating and 
assembly 
instructions
                       

EN

Summary of Contents for S-LP 133/62

Page 1: ...11 31973 5000 info elektror de www elektror de S LP S LP 133 62 S LP 146 74 S LP 160 62 S LP 180 74 S LP 200 74 S LP 200 92 S LP 215 92 S LP 225 92 S LP 250 104 S LP 315 103 Elektror Edel stahl Nieder...

Page 2: ...ftige explosionsf hige oder Medien ist nicht zul ssig Die maximale Temperatur des F rdermediums darf bei der Serienausf hrung 20 C bis 80 C nicht berschreiten Son derausf hrungen mit Temperatursperre...

Page 3: ...rschutz w hrend des Betriebs Bei Nichtbeachtung sind Geh rsch den die Folge Die vom Ventilator abgestrahlten Ger usche sind nicht ber den gesamten Leistungsbereich konstant Die abgestrahlten Ger usch...

Page 4: ...en Betrieb nach fehlerhafter Montage Instandhaltung oder nicht abgestimmtem Austausch von Bauteilen f hrt zu nicht bestimmungsgem em Gebrauch und zum Verlust der Ge w hrleistung Das entstehende Risiko...

Page 5: ...r Impulsspannungen max 1000 Vpk f r Antriebsmotoren bis 0 75 kW max 1300 Vpk f r Antriebsmotoren gr er 0 75 kW an den Motorklemmen m ssen geeignete Ma nahmen wie z B ein Motorfilter zum Schutz des Mot...

Page 6: ...rekt aufgebautem Frequenzumrichter erf llen unter Ber cksichtigung der EMV Hinweise des Frequenz umrichterherstellers und den Angaben in der Elektror Be triebs und Montageanleitung die Anforderungen a...

Page 7: ...rin zipbedingt Ableitstr me 3 5 mA Diese Ableitstr me k n nen zu Fehlausl sungen in Anlagen f hren die ber einen 30 mA FI Schutzschalter abgesichert sind Im Fehlerfall k nnen Fehlerstr me auch als Gle...

Page 8: ...d rfen z B den Wuchtzustand des Laufrades nicht verschlechtern Stellen Sie vor Wiederinbetriebnahme des Ventilators sicher das alle Werkzeuge oder sonstigen Fremdk rper aus dem Ger teinneren entfernt...

Page 9: ...en Maschine ist so lange untersagt bis festgestellt wurde dass die Maschine in die die unvoll st ndige Maschine eingebaut werden soll den Bestimmungen der Maschinenrichtlinie 2006 42 EG entspricht Die...

Page 10: ...potentially explosive or media is not permissible The maximum temperature of the conveyed medium must not exceed 20 C to 80 C in the standard version Special versions fitted with a thermal barrier fo...

Page 11: ...tion may be necessary it is rec ommended that emission levels be measured by the opera tor Sound insulation must be provided by the operator to avoid exceeding the statutory maximum levels at the work...

Page 12: ...onal load on blower refer to ISO 14694 BV 3 Measurement at the flange bearing shield preferably near the bearing Measuring point Measuring direction Maximum permissible vibration speed Limit values ac...

Page 13: ...rements in the operating instruc tions of the frequency converter motor filter manufacturer The maximum cable length between the mo tor and switch cabinet frequency converter e g Lenze Vector Omron MX...

Page 14: ...mation Please observe the notes on designated use in section 1 1 as well as the safety guidelines in sections 1 2 to 1 11 If electrical current exceeds the rated current of the drive mo tor during ope...

Page 15: ...d and other influences such as temperature etc Maintenance and servicing may only be performed by per sons with the necessary expertise and regular training In ad dition to the appliance s operating i...

Page 16: ...parts are made of recyclable material such as aluminium stainless steel copper and plastic However there are components that need special treatment e g fre quency converters The statutory national and...

Page 17: ...is not permitted until it has been verified that the machine in which the partially completed machine is to be installed complies with the provisions of the Machinery Directive 2006 42 EC The followin...

Page 18: ...18 DE Betriebs und Montageanleitung S LP www elektror de 9016326 01 20 06 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 16 16 18 15 9 EXPLOSIONSZEICHNUNG BROKEN VIEW DRAWING...

Page 19: ...raube Screw 7 Ventilatorfu Blower base 8 Ventilatorgeh use Blower housing 9 Laufrad Impeller 10 Scheibe Washer 11 Schraube Screw 12 Ansaugring Suction ring 13 Schutzgitter Wire mesh guard 14 Schraube...

Page 20: ...ence Voltage Frequency Power consumption Motor speed Motor output Weight approx Min max sound pressure level 1 Ball bearing designation 2 m min Pa V Hz A min 1 kW kg db A S LP 133 62 12 5 575 230 400...

Page 21: ...rmation on installation operation and maintenance of the ventilatorto minimise its environmental impact and to ensure an optimal service life Description of other items used to establish the energy e...

Page 22: ...22 DE Betriebs und Montageanleitung S LP www elektror de 9016326 01 20 06...

Page 23: ...23 DE www elektror de Betriebs und Montageanleitung S LP 9016326 01 20 06...

Page 24: ...m Internet unter www elektror de Gerne steht Ihnen auch unser Produktmanagement unter der Rufnummer 49 711 31973 1111 zur Verf gung You will find further information about our products on the internet...