Elektror HRD 2 FU-130 Series Operating And Assembly Instructions Manual Download Page 22

22

Y

 ( 1

 /

 2

 )

Y

16

15

6

5

17

20

22

23

24

25

26

20

27

29

28

21

A

n

zieh

mo

me

nt 

75

 N

m

Tightening torque

75

 N

m

1

2

8

6

5

4

7

5

6

3

18

19

9

10

11

12

10

13

14

www.elektror.com

9016341 07.20/12

10

  EXPLOSIONSZEICHNUNG

 FÜR

 GERÄT

 HRD

 7

 FU

-120

10

 BROKEN

 VIEW

 DRA

WING

 FOR

 DEVICE

 HRD

 7

 FU

-120

Summary of Contents for HRD 2 FU-130 Series

Page 1: ...HRD Boosted Hochdruckventilator Betriebs und Montageanleitung DE High pressure blower Operating and assembly instructions EN HRD 2 FU 130 HRD 60 FU 135 HRD 7 FU 120 www elektror com...

Page 2: ...Eintritt in den Ventilator ausgefiltert werden Bei Kondensatbildung empfehlen wir eine Kondenswasser bohrung an der tiefsten Stelle im Geh use Der Ventilator ist ohne besondere Ma nahmen nicht f r di...

Page 3: ...dk rper und nicht zul ssigen Medien besteht die M glichkeit dass Gegenst nde mit hoher Geschwindigkeit aus dem Auslass des Ventilators geschleudert werden Vergewissern Sie sich dass der Ventilator nur...

Page 4: ...ng unterzogen werden Aufstellung Montage Betrieb und Instandhaltung d rfen nur von fach und sachkundigem Personal durchgef hrt wer den Betrieb nach fehlerhafter Montage Instandhaltung oder nicht abges...

Page 5: ...st tigt wurden Die Versorgungsspannung des Frequenzum richters darf ohne Motorfilter maximal 400 V betragen Bei h heren Umrichter Versorgungs spannungen l ngeren Leitungen und oder ber schreitung der...

Page 6: ...r die ganze Kennlinie einsetz bar sind max Volumenstrom siehe Leistungsschild kann bei zu geringem Anlagenwiderstand der Motor berlastet werden zu hohe Stromaufnahme Drosseln Sie den Vo lumenstrom in...

Page 7: ...mpfehlungen der gesam ten Anlage folgendes zu beachten Inspektions und Wartungsintervalle In Abh ngigkeit von Betriebsstunden Belastungen und Ein satzbedingungen hat der Betreiber das Reinigungs Inspe...

Page 8: ...SRELEVANTE INFORMATIONEN BER AUSSERBETRIEBNAHME UND ABBAU Das Trennen aller elektrischen Verbindungen und aller wei teren elektrotechnischen Ma nahmen in Verbindung mit der Au erbetriebnahme darf nur...

Page 9: ...ntersagt bis festgestellt wurde dass die Maschine in die die unvollst ndige Maschine eingebaut werden soll den Bestimmungen der Maschinenrichtlinie 2006 42 EG entspricht Die folgenden harmonisierten N...

Page 10: ...e at the lowest point in the housing in the event of formation of condensation The blower is not suitable for installation outdoors without special measures Rubber pads are installed between the motor...

Page 11: ...t direct contact Risk of burning There may be an increase in the temperature of the medium to be conveyed particularly with higher pressure models when conveying the medium from the air intake side to...

Page 12: ...haft Rubber pads are installed between the motor and motor console with blowers HRD 60 FU 135 and HRD 2 FU 130 Rubber pads are installed below the base plate with blower HRD 7 FU 120 These are supplie...

Page 13: ...OTEC frequency converters Further information on wall mounting close to the motor can be found in the original operating and assembly instructions of the respective frequen cy converter manufacturer T...

Page 14: ...ge break contact Values see rating plate The motor can be operated in a delta or star connection depending on the converter input voltage The following U f assignments must be configured at the conver...

Page 15: ...time for replacing the bearings is the sole responsibility of the main tenance and servicing personnel who must make a safety judgement Devices Minimum ball bearing service life Horizontal motor shaf...

Page 16: ...owever there are components that need special treatment e g fre quency converters The statutory national and local disposal and recycling regulations must be observed 7 LIABILITY AND EXCLUSION OF LIAB...

Page 17: ...een verified that the machine in which the partially completed machine is to be installed complies with the provisions of the Machinery Directive 2006 42 EC The following harmonised standards have bee...

Page 18: ...18 www elektror com 9016341 07 20 12...

Page 19: ...rm blower speed Motor speed Voltage Frequency Power consump tion Motor output Weight Sound pressure level min max 1 m min Pa min 1 min 1 V Hz A kW kg db A HRD 2 FU 130 7 5 23 0 14600 7800 7670 400 130...

Page 20: ...20 www elektror com 9016341 07 20 12 10 EXPLOSIONSZEICHNUNG F R GER T HRD 2 FU 130 UND HRD 60 FU 135 10 BROKEN VIEW DRAWING FOR DEVICE HRD 2 FU 130 AND HRD 60 FU 135...

Page 21: ...ower housing 12 Laufrad Impeller 13 Scheibe Disc 14 Wellenmutter YN Shaft nut YN 15 Geh usedeckel Housing cover 16 Schutzgitter Wire mesh guard 17 Sechskantschraube Hexagonal screw Bei Bestellung folg...

Page 22: ...25 26 20 27 29 28 21 Anziehmoment 75 Nm Tightening torque 75 Nm 1 2 8 6 5 4 7 5 6 3 18 19 9 10 11 12 10 13 14 www elektror com 9016341 07 20 12 10 EXPLOSIONSZEICHNUNG F R GER T HRD 7 FU 120 10 BROKEN...

Page 23: ...be DIN 912 M12 x 50 Cylinder head screw DIN 912 M12 x 50 16 Motor VAF 132FM Motor VAF 132FM 17 Sechskantmutter ISO 4032 M12 Hexagon nut ISO 4032 M12 18 Seitenb gel rechts Sidebar right 19 Seitenb gel...

Page 24: ...nen Ventilator sind immer jeweils 2 Einheiten erforderlich Der Antrieb B ist wiederverwendbar Das Batterie Set C muss j hrlich getauscht werden Die LC Einheit D ist nicht wiederbef llbar Die Nachschmi...

Page 25: ...evolutions per minute at optimal energy e ciency Specifi c relationship Information to simplify disassembly recycling or disposal after fi nal decommissioning Information on installation operation and...

Page 26: ...26 www elektror com 9016341 07 20 12...

Page 27: ...27 www elektror com 9016341 07 20 12...

Page 28: ...www elektror com Elektror airsystems gmbh Hellmuth Hirth Str 2 73760 Ostfildern Postfach 1252 73748 Ostfildern Telefon 49 711 31973 0 Telefax 49 711 31973 5000 info elektror de 9016341 07 20 12...

Reviews: