36
Reversing function
Menu "2.5":
Limiting of the number of reversing movements following safety edge system activations via
automatic closing.
If the set value is exceeded, automatic closing is deactivated and the "F2.2" fault indication is
displayed.
Note!
To reset fault "F2.2": Move to CLOSE final limit position
X3: Input, emergency stop
Connection of an emergency stop control device as per EN 13850 or an evaluation unit for an
anti-trap safety device. The “F1.4” fault indication appears upon activation.
Note!
FI-drive units: Drive units are de-energised as a result of an emergency stop