PUTTING INTO OPERATION WITHIN PocketHome
®
SYSTEM
If the display shows no data, it is necessary to connect PH-TS20 to 230V/50
Hz socket and let it charge for approximately 12 hours. When the back-up bat-
tery is fully charged, the display is active and no message dObI should be
present, only then the socket may be programmed!
If the PH-TS20 is not connected to the socket, it shows temperature which is
by 1.5°C lower than real temperature!
1. FIRST CONNECTION
3. SOCKET ACTIVATION
-
ESTABLISHING THE COMMUNICATION WITH CENTRAL UNIT
3
2. TIME SETTING - CL:O FUNCTION
current time and day
!
- connect PH-TS20 to distribution network 230 V/ 50Hz until the symbol
dObI
disappears
from the display (it warns that it is necessary to charge the back-up battery)
- when charged, activate according to below given procedure
- the appliance to be regulated is to be connected by simple
insertion to PH-TS20 socket
- to be installed in areas with relative humidity lower than approx. 95%
It is not necessary to set the time as it is synchronized
automatically with central unit PH-CJ37!
Current time is sent to all sockets at each time change
(central unit displays TS).
It applies also to the connection of PH-CJ37 to PC!
- press
, by means of
select function for socket
activation
UA:dr
and confirm by
- nunique factory number
*
shows on display
- press ”
Test
” on central unit in
ACTIV
mode for given socket
(see the manual for PH-CJ37)
- address
Pa:r8
is assigned automatically
- within 1 minute, the socket is activated in PocketHome
®
system and is preferentially controlled from central unit
PH-CJ37 (AUTO+MANU items are shown on the display
simultaneously and also current time/temperature).
Fce
i
Before the socket can be activated, it is necessary to set and prepare central
unit according to instructions for PH-CJ37! (poss. also SW for PC)
*
unique number
: Each central unit has its unique, factory set number, which prevents
mutual interference of PocketHome
®
systems!