ELEKTROBOCK PocketHome PH-TS20 Operating Instructions Manual Download Page 10

TECHNICAL PARAMETERS

Power

230 V/ 50 Hz

Communication type

two-way 

Frequency

433,92 MHz

Range

300 m 

(in open area), 

35 m 

(in built-up area)

Number of temperature changes 

6 changes of temperature for each day

Hysteresis

0,1°C to 2°C with steps of 0,1°C

Minimal programmable time

10 minutes

Range of possible temperatures

3 to 40°C

Temperature setting

step of 0,5°C

Minimal step of indication

0,1°C

Measurement accuracy

±0,5°C

Back-up battery

NiMh 3.6 V, > 100 hours

Protection

IP20

Output

relay, max.16 A

Operating temperature

0 to 40°C

WARRANTY CERTIFICATE

(a 2-year warranty is granted for the product)

Product number:

Date of sale:

Shop stamp:

Checked by:

MADE IN CZECH REPUBLIC

Send the socket for guarantee and after-guarantee service to manufacturer’s address.

ELEKTROBOCK CZ s.r.o.

Blanenská 1763
Kuřim 664 34 

Tel./fax: +420 541 230 216

www.elbock.cz

in compliance with RoHS

Pb

Pb

LEAD FREE

ES DECLARATION OF COMPLIANCE

We, ELEKTROBOCK CZ s.r.o., herewith declare that the PH-TS20 product is in compliance with princi-
pal requirements and further respective stipulations of the directive 1999/5/ES. 
Issued: 1.09.2007

www.elbock.cz

PH-TS20 is wireless thermally switched socket for automatic regulation
of electrical heating and cooling systems (direct heating bodies, towel
driers, fires, air-conditioners, ventilators) in family houses and offices. 
Its benefits include the possibility to set HYSTERESIS and the presence
of back-up battery which keeps the parameters set also in the case of
power failure.

Summary of Contents for PocketHome PH-TS20

Page 1: ... communication on 433 92 MHz It switches on off connected appliance according to required temperature Current temperature measuring with built in sensor Central unit PH CJ37 acts as a superior component Power supply 230 V 50 Hz Operating instructions PH TS20 version 10 07 NEW FEATURES SUMMER MODE FOR SWITCHING THE AIR CONDITIONER ON OFF ...

Page 2: ... t current time temperature CL O tE P sum of operating hours SU MA and day dE n setting of temperature time functions browsing socket for controlled appliance DISPLAY DESCRIPTION indication of operational mode or selected function indication of time temperature indication of temperatures comfort economy party indication of set time and temperature program displayed only in autonomous mode 2 i Fce ...

Page 3: ...e insertion to PH TS20 socket to be installed in areas with relative humidity lower than approx 95 It is not necessary to set the time as it is synchronized automatically with central unit PH CJ37 Current time is sent to all sockets at each time change central unit displays TS It applies also to the connection of PH CJ37 to PC press by means of select function for socket activation UA dr and confi...

Page 4: ...N When the socket is activated in the system within UA dr mode see p 3 each socket is gradually assigned with address from 1 to 255 This address cannot be changed but the socket can be deactivated from PocketHome system press by means of pressing the function for parameters setting PA r and confirm by pressing by means of select parameter PA r8 and again confirm by by means of it is possible to de...

Page 5: ...for manual setting of temperature selected by or by buttons the temperature will be constant up to the next change of mode CLO setting of current day and time PROG programming mode PAr setting of parameters constants OFF in this mode the socket is permanently switched off UAdr mode for socket activation in PocketHome system P Fce Note If no button is pressed in 2 minutes the socket returns to its ...

Page 6: ...ct in inverse way than in the mode for heating if PA r5 0 5 and required temperature is 23 C the socket switches on at the temperature of 23 5 C by pressing select mode then press button i i P 6 PA r5 HYSTERESIS factory setting 0 5 C PA r5 is showed on the display confirm by and by pressing buttons set hysteresis in the range from 0 1 C to 2 C again confirm by pressing i i HYSTERESIS temperature d...

Page 7: ...epeated until all time intervals max 6 are set and afterwards leave the programming mode by pressing select AUTO function and the socket starts to function according to defined program Fce Indication of socket condition in autonomous mode symbol AUTO or MANU on the display IS ALIGHT connected appliance is SWITCHED ON symbol AUTO or MANU on the display FLASHES connected appliance is SWITCHED OFF EX...

Page 8: ...e are showed alternatively on the display To cancel this function press button and select different mode with using of buttons Fce i Fce OFF FUNCTION permanent switching off It serves for keyboard blocking as a protection against unauthorized handling Press button then simultaneously press and now the keyboard is blocked the buttons are inoperative Message LOC LOCK is shortly displayed on the disp...

Page 9: ...S SOON AS THE TEMPERATURE DROPS UNDER REQUIRED TEMPERATURE THE PH TS20 SWITCHES THE APPLIANCE ON SUITABLE FOR DIRECT CONTROL OF FOL LOWING APPLIANCES ELECTRICAL TUBULAR RADIATORS ELECTRICAL HEATING PLATES DIRECT HEATING BODIES VENTILATORS AIR CONDITIONERS WITH CENTRAL UNIT PH CJ37 IT IS POSSI BLE TO MONITOR CURRENT TEMPERATURE AND CONDITION OF CONNECTED APPLI ANCE AND TO SEND REQUIRED CHANGES OF T...

Page 10: ...by MADE IN CZECH REPUBLIC Send the socket for guarantee and after guarantee service to manufacturer s address ELEKTROBOCK CZ s r o Blanenská 1763 Kuřim 664 34 Tel fax 420 541 230 216 www elbock cz in compliance with RoHS Pb Pb LEAD FREE ES DECLARATION OF COMPLIANCE We ELEKTROBOCK CZ s r o herewith declare that the PH TS20 product is in compliance with princi pal requirements and further respective...

Reviews: