28 ZMENA CASU
HOd PROVOZU UT
VENKOVNI TEPLOtA
TEPLOTA A VYKON
POZAdOVANA TUV
HOd PROVOZU TUV
29
29. VERSION (factory reset)
Firmware version, information only.
If you press and hold (approx. 3 s) the button “ “,RESET appears briefly on the LCD
and the thermostat returns to the factory settings!
15
28. TIME CHANGE (factory setting YES)
If YES, DST / WINTER time is automatically changed according to the calendar. You don‘t
have to watch when the time changes, the thermostat will take care of the automatic
time setting for the given period.
MORE INFORMATION
By successively pressing the button “ “ in AUTO / MANU modes, additional information can be obtained, which
the boiler transmits to the thermostat (note that this information may be different depending on the boiler type):
QUICK CHANGE OF REQUIRED TEMPERATURE / PROGRAM
Press twice “ “, the required temperature flashes on the display. By turning the button “
“ change the desired temperature and press the button “ “ for more information or
“ “ to return to the main menu.
In AUTO mode
the change will last until the next change given by the program. In this
mode, you can select another program in the same way.
In MANU mode
the change will be permanent.
OUTDOOR TEMPERATURE INFORMATION
Information about the current outdoor temperature.
The condition is a connected
sensor at the boiler!
INFO ABOUT UT TEMPERATURE AND MODULATION POWER
Required UT
= calculated UT temperature according to the selected equithermal cur-
ve, without regardless of min. and max. possible water temperature UT.
Actual UT
= current water temperature UT
Modul performance
= boiler modulation output in%
UT AND TUV OPERATING HOURS
Indication of operating hours of the boiler for DHW and DHW heating. The indication on
the LCD means 906 hours 43 minutes (max. 9999 hours 999 minutes).
Clock reset:
After displaying the operating hours, turn the button “ “ to the left (counterclockwise).
Press 4x the button “ “, the LCD shows the required DHW temperature set
in the program for DHW (Pr t). By turning the button “ “ change the desired tempera-
ture and press the button “ “ to return to the main menu.
0 = off, range 10 to 65 ° C up to 1 ° C.
SHORT - TERM CHANGE OF REQUIRED DHW TEMPERATURE