Handling the device
Remote control
Set values can be put in externally via the pins VSEL
and CSEL and with analogue voltages of 0...10V.
The power output values are put out as monitor si-
gnals VMON and CMON in a range of 0...10V.
In order to control the set values remotely, the „remo-
te“ control has to be activated first. This is done by
pulling pin 7 „Remote“ to low. If required, one of the
set values can be bridged to the reference voltage
VREF and will thus be 100%.
Remote control is indicated by the LED „External“.
For pin assigment of the analogue interface see next
page.
Application examples for the analogue
interface
Remotely switching output on / off
Digital input (DI)
The input can be used to switch off the device output
at any time. After this, switching it on again is only
possible by releasing the contact or switch.
The contact/switch on pin 8 overrides the pushbutton
„On/Off“. Switching to remote control by pin 7 is not
required.
Monitoring voltage and current
Analogue outputs (AO)
Front view