57
EN
Instruction Manual
PSI 8000 2U Series
Date:04-26-2011
Using the power supply
Analogue in./out.
selects the voltage range for the analogue
set values inputs and actual value outputs:
Analogue voltage
Default:
0...10V
= 0...10V
Selects 0...10V for 0...100% set/actual values.
= 0...5V
Selects 0...5V for 0...100% set/actual values.
The reference voltage at pin VREF is automatically adjusted to
the above selection and will be either 5V or 10V.
Digital inputs
defines if the digital control inputs will act at
LOW or HIGH level.
REMOTE /5
Default:
LOW
= LOW
Unit switches to analogue remote control, if
the pin is tied to LOW (ground).
= HIGH
Unit switches to analogue remote control, if
the pin is tied to HIGH.
Caution! This pin is tied to HIGH level by default. It means,
that if setting
HIGH
is chosen and the pin is left open, the
device will permanently stay in analogue remote control!
Pin Name
Type
(1
Description
Level
Electrical specification
1
VSEL
AI
Set value: voltage
0…10V or 0...5 correspond
to 0..100% of U
Nom
Accuracy < 0,1%
Impedance R
i
>100k
2
CSEL
AI
Set value: current
0…10V or 0...5V correspond
to 0..100% of I
Nom
3
VREF
AO Reference voltage
10V or 5V
Accuracy < 0.2% at I
Max
= +5mA
Short-circuit-proof against AGND
4
DGND
POT Reference potential for
digital control signals
For +Vcc, control and status signals
5
REMOTE
DI
Toggle between internal
or external control
External = LOW, U
Low
<1V
(4
Internal = HIGH, U
High
> 4V
Internal = open
U range = 0 …30V
I
Max
= +1mA at 5V
Sender: Open collector against DGND
6
OT
DO Overtemperature error OT = HIGH, U
High
> 4V
no OT = LOW, U
Low
<1V
(4
Quasi open collector with pull-up to Vcc
(2
At 5V at the output there will be max.+1mA
I
Max
= -10mA at U
CE
= 0.3V
U
Max
= 30V
Short-circuit-proof against DGND
7
N.C.
Not connected
8
PSEL
(3
AI
Set value: power
0…10V or 0...5V correspond
to 0..100% of P
Nom
Accuracy < 0.5%
Impedance R
i
>100k
9
VMON
AO Actual value: voltage
0…10V or 0...5V correspond
to 0..100% of U
Nom
Accuracy < 0.1% at I
Max
= +2mA
Short-circuit-proof against AGND
10 CMON
AO Actual voltage: current 0…10V or 0...5V correspond
to 0..100% of I
Nom
11 AGND
POT Reference potential for
analogue signals
For -SEL, -MON, VREF signals
12 +Vcc
AO Auxiliary voltage output
(Ref: DGND)
11...13V
I
Max
= 20mA
Short-circuit-proof against DGND
13 REM-SB
DI
Output off
off = LOW, U
Low
<1V
(4
on = HIGH, U
High
> 4V
on = OPEN
Voltage range = 0…30V
I
Max
= +1mA at 5V
Sender: Open-Collector against DGND
14 OVP
DO Overvoltage error
OVP = HIGH, U
High
> 4V
no OVP = LOW, U
Low
<1V
(4
Quasi open collector with pull-up to Vcc
(2
At 5V at the output there will be max.+1mA
I
Max
= -10mA at U
CE
= 0.3V
U
Max
= 30V
Short-circuit-proof against DGND
15 CV
DO Indication of voltage
regulation active
CV = LOW, U
Low
<1V
(4
CC = HIGH, U
High
>4V
(1
AI = Analogue input, AO = Analogue output, DI = Digital input, DO = Digital output, POT = Potential
(2
Internal Vcc = 13...15V
(3
Only with models from 1kW
(4
Default setting, can be changed in device setup