The final stage of brake installation
7.
onto the motor is mounting the fan and
inserting the brake supply cable into
the motor terminal box,
Connect the brake supply cable inserted
8.
into the motor terminal box according
to the diagram on the inside of the box
cover, while connecting the brake with
the motor maintain all the necessary
safety measures and precautions
pertaining to the handling of electrical
equipment,
Mounting the motor casing onto the
9.
brake and fan completes installation of
the brake.
BRAKE AIR GAP ADJUSTMENT
Adjustment of the air gap is
performed each time after
ascertaining that the brake
air gap has attained the
maximum value as in Table 1,
and always after dismounting
the brake and replacement
or maintenance of damaged
subassemblies.
For this purpose:
Dismount the motor
1.
casing,
Remove the brake casing
2.
(7),
Loosen the mounting
3.
bolts (6) using the Allen
key of the size according
to Table 2 - by unscrewing
them half a turn,
Screw in the regulating
4.
bolts (8) into the
electromagnet body by
one turn, for screwing in
the bolts use the flat key
according to Table 3,
Table 3
Key Size
(mm)
HPS 06
HPS 08
HPS 10
HPS 12
HPS 14
HPS 16
HPS 18
HPS 20
HPS 25
10
10
12
12
14
14
14
17
17
Elektrim Brake Service Manual
7