20
6.4.10 Factory Reset
This menu allows a factory reset which resets all settings to factory
default except the Global Counter and Vends Total.
6.5 Testing and Cleaning
6.5.1 Manual Cleaning
Manual cleaning mixers are used for performing manual cleaning
procedure. After pressing the
SUGAR(-) (SELECT) button choose
the required mixer displayed on the screen then press the
SUGAR(-) (SELECT) button again to complete the procedure.
6.5.2 Self Cleaning
In the Automatic Cleaning Menu press the SUGAR(-) (SELECT)
button for the machine to start cleaning its mixers using the water
in the boiler.
Place a 200
–
300 ml sized empty cup under the
drinks dispenser when performing SELF cleaning procedure.
6.5.3 Function Test
During the function test the canister motors and the mixer motors
rotate in turns. Motors test is done this way. To prevent powder
products spillage on the mixers, Ingredient Canisters should be
empty when performing Function Test.
6.5.4 Cup Dispenser Test
Cup Dispenser Test is used to test if the Cup Dispenser is operating
normally
6.5.5 Trial Mode
The Trial Mode allows dispensing drinks without any payment.
6.6 USB Menu
This menu allows software upgrade via a USB disk and also allows
the statistical data to be transferred to a computer.
USB MENU
[6]
DAFAULT
SETTINGS APPLY?
DAFAULT SETTINGS
[4/10]
CUP DISPENSER
[5/4]
SELF CLEANING
[5/2]
FUNCTION TEST
[5/3]
TEST & CLEANING
[5]
MANUEL CLEANING
[5/1]
[5/31]
CLEAN MIXER 1
[5/31]
SELF CLEANING
APPLY?
TRIAL MODE
[5/5]