MIG/MAG
MIG/MAG
MIG/MAG
180/35 ET
200/35 ET
230/40 ET
Combi
Welding range
25 - 180 A
25 - 200 A
25 - 230 A
Open-circuit voltage
15.3 - 23 V
15.3 - 24 V
15.3 - 25,5 V
No-load voltage
17.5 - 33 V
21 - 34 V
19 - 34 V
Input capacity
3.6/4.6 kVA
6 kVA
6.5 kVA
Mains 50/60 Hz AC
1 ~ 230 V/2 ~ 400 V
3 ~ 400 V
3 ~ 400 V
Frequency
50-60 Hz
50-60 Hz
50-60 Hz
Welding steps
6
6
6
Wire diameter
0.6 - 0.8 mm
1,0 mm
0.6 - 1.0 mm
Weldable material
0.5 - 6 mm
0.5 - 7 mm
0.6 - 9 mm
Duty cycle (25
°
c/ 40
°
C )
180 A 35%/25%
200 A 35%725%
230 A 40%/30%
100% (25
°
c/ 40
°
C )
100 A/70A
110 A/75A
140 A/100A
Mains fuse
T 16 A
T 16 A
T 16 A
Cooling
F
F
F
Protection class
IP 21
IP 21
IP 21
Isulation class
F
F
F
Welding gun assembly
SB 15/2
SB 15/2
SB 25/2
Dimensions l x w x h
840x410x580
840x410x580
840x410x580
Weight
68 kg
75 kg
81HAM kg
StandardScope of delivery:
Welding machine with MIG/MAG torch c/w contact tip and gas shroud, pressure
regulator for shielding gas, earth clamp, wire brush and nozzle anti-clogging spray.
delivery:
2
Regulations for the Prevention of Accidents
Know the applicable regulations for electric arc welding and strictly adhere to.
Safety Instructions
●
Protection against electrical accidents
- Welding cables are to be firmly connected to ensure proper conducting capacity
- Mains cord and welding cables are to be protected against damages.
- Replace damaged mains cords with genuine Elektra Beckum parts only.
- Place welding gun onto insulating backing during short work break.
- For longer breaks switch off machine.
- When welding, wear dry and insulating gloves and shoes.
- For maintenance and repair work disconnect from power mains.
●
Protection against UV rays, burns and fumes
- Wear protective clothing to prevent burns (sleeved gloves, welding apron etc.)
- Always use a welding visor.
- Screen off work place to protect other persons working nearby against UV rays.
- Welding material having a polluted or contaminated surface may generate toxic fumes. Clean surface before
welding.
- Zinc-plated or galvanized material should not be welded as zinc fumes are highly toxic.