8 • Stand-alone mode
●
21
A long press on this button enables/disables the display of the
measurement chain parameters: Range from 1 to 4, PGA gain
in voltage measurement (1 or 3 or 10), PGA gain in current
measurement (1 or 3 or 10).
21. Range -> 2 (R2)
PGA_U -> gain of 1 (U1)
PGA_I -> gain of 3 (I3)
• The function of the [MENU] button is known:
- a short press gives access to the user settings,
- a long press gives access to the calibration menus.
8.1 User menu
8.1.1 Language
Allows the choice of the language used for the menus: English, French,
German, Dutch, ....
8.1.2 Qlimit for secondary display
Selection of the Q value (= 1/D) above which the secondary parameter
is not displayed. The possible values are:
100 200 500 1000 2000 5000 no limit
8.1.3 Sorting parameters
This menu allows you to select the parameters (tolerance and value)
used for sorting components. The proposed value will be the main
parameter of the connected reference component
before
entering the
menu mode. These parameters will be stored in memory.
The first step allows you to select the standard tolerance, from the E6
series (20%) to the E96 series (1%).