IMPORTANT

Installer and Users please note:

These instructions should be read carefully and left with the user of

the product for future reference.

BEFORE USE

Inspect the product for any signs of damage. If the product is

damaged, DO NOT use it, and contact your supplier immediately. 

PRODUCT SAFETY

 Do not use unless correctly installed.

 Do not cover when in use. 

GENERAL SAFETY REQUIREMENTS

Domestic wiring must be tested periodically by a qualified electrician

at least once every 10 years or at every change of occupancy.

For office and retail premises, and buildings such as village halls, the

wiring must be inspected at least once every 5 years.

It is recommended that all building be fitted with smoke alarms (it is

mandatory for new buildings).

INSTALLATION

The L300B/BW must be installed by a competent electrician in

accordance with the current IEE Wiring Regulations. 

Mains input.

 Remove the two cover fixing screws, and hinge the

top cover downwards. Connect the L300B/BW to a lighting circuit

fused at 6 A. If being installed outdoors, use suitable cable such as

H07RNF (tough rubber sheath) with a minimum cross sectional

area of 1.0mm

2

. Pass the cable through the cable gland, and

connect to the terminal block. 

 Connect Live to the terminal labelled "L".

 Connect Neutral to the terminal labelled "N".

 Connect Earth to the terminal labelled with the earth symbol.

 The L300B/BW must be earthed.

Tighten the cable gland to make sure that a good, waterproof seal is

obtained.

Inserting a lamp.

 Use a 70 W RX7s metal halide lamp. 

Holding the lamp with a cloth or piece of plastic to avoid touching

the glass, push the lamp against the spring of the lampholder. Push

Page 2