13
U.S. and Foreign Patents Pending
1.
OPTIONAL: Add a CLEARLINE treated strainer return line
with a tee-fitting and ball valve, after the ClearCell Flow Sensor that goes back to the
strainer.
This CLEARLINE treated strainer return line should be connected
after the ClearCell Flow Sensor output
and return to the strainer
lid or after the seacock. The CLEARLINE treated return line to the strainer should be 3/8” (9.5mm) ID flexible hose and should include a ball
valve to adjust return flow as necessary.
DO NOT connect the return line source before the pump on the suction side.
2.
There are two options to install the CLEARLINE treated return line to the strainer:
2A.
Use CLEARLINE Strainer Accessory Kit to plumb the return line directly to the top of the strainer lid.
The CLEARLINE Strainer Accessory Kit includes a custom strainer lid, ball valve, tubing, connectors and fittings.
DO NOT drill through the top of any strainer lid.
The lid will crack and/or fail over time and could resulting in sinking of the vessel.
2B.
Use the appropriate plumbing fittings to connect the return line after the seacock and
before the strainer. Make sure to use a ball valve.
NOTICE
ClearCell Installation
13
Optional Strainer Return Line
PART NUMBER
DESCRIPTION
DSA-1.5
Arctic Steel 1.5” (3.8cm) Dual Strainer Accessory
DSA-SP1
SCOT Pump Dual Strainer Accessory
WARNING
2A
Air Conditioner
Thru-hull
Intake
Cooling Condenser
Raw Water
(Outflow)
CLEARLINE
Treated Seawater
DC Power
Supply
Secondary CLEARLINE Treated
Strainer Line
Primary CLEARLINE Treated
Cooling Line
Seawater
Pump
Strainer
Seacock
CLEARLINE
CONTROL UNIT
2A
2B
1