-8-
+
3
7
7
4
4
8
5
9
6
LOAD
(100mA max.)
AUX PGM
2.3: Terminal Connections
15-16.5Vac Input
Terminals 1 & 2:
Connect a 15Vac transformer
rated at 22-30VA, using 18 AWG wire.
Auxiliary Power Output
Terminals 3(+), 4(-):
The auxiliary power output connections supply power to keypads
and peripheral units such as detectors and other powered sensors.
Keypad Data Bus Connections
Terminals 5 & 6:
Connect up to three individually addressed LED keypads to terminals
5 (K2), and 6 (K1). Make sure that the wires are connected to the same connections on
the keypad, see 2.4: Mounting the Keypad.
Bell Power Output
Terminals 7(+), 8(-):
Connect these terminals to supply power
to the bell. The bell power output supplies AUX power, rated at
600mA max.
Bell Supervision (USA hardware only)
The bell connections must be terminated by a 2.2K ¼W
resistor as shown in Figure 2.1.
PGM Programmable Output
Terminal 9:
The PGM output switches to
ground when activated, enabling the
connection of additional system status
indicators. Connect the PGM output as
shown in the Figure 2.2.
Tamper Zone/Keyswitch Connections
Terminal 10:
Connect a tamper switch or ON/OFF keyswitch
to terminals 10(+) and 12(-).
Note: If neither the tamper
zone nor keyswitch are used, short terminal 10 to 12 and
define this zone as Tamper Zone at Address 01.
Zone Connections
Terminals 11, 12, 13, 14, 15 & 16:
ZONE 1: Terminals 11(+) & 12(-) ZONE 3: Terminals 14(+) & 15(-)
ZONE 2: Terminals 13(+) & 12(-) ZONE 4: Terminals 16(+) & 15(-)
10
11
12
+
Tamper Switch or
ON/OFF Keyswitch
2.2K
7
8
+
Figure 2.1: Bell
Supervision Connections
Figure 2.2: PGM Output Connections
Figure 2.3: Tamper Zone/
Keyswitch Connections