-5-

3.2: Command Codes

The Penta security system is operated by entering command codes on the numeric
keypad. A command is executed by pressing the ‘

Q

‘ button followed by the

corresponding command number. In some cases, a valid user code is also required.
The following is a summary of the command codes used in system operation.

Q

0

Quick Arm

Q

5

 

+ (User Code 1)

Program User Codes

Q

1

 

+ (User Code)

Bypass Mode

Q

6

Zone Chime

Q

2

Emergency/Trouble
Event Log

Q

8

 

+ (User Code)

Forced Arming

Q

3

Zone Alarm
Event Log

Q

9

 

+ (User Code)

Stay Arming

Q

41

Q

42 + (User Code 1)

Bell/LED Test
Walk Test

ENTER 1

 

+ (User Code 1)

Stop Communications

3.3: Keypad Tones

The keypad sounds various tones to indicate the following:

 Short Beep – Confirmation of each keystroke

 Half Second Beep – Acknowledgement of a successful command entry

 Low Beep – Rejection of an illegal command entry

 Continuous Beeps – Entry/Exit Delay in progress

3.4: User Codes

User codes are the codes that grant you access to various system operations, such as
arming and disarming. Each user code is four digits long. Of the four user codes, only
User Code 1 has the authorization to program other user codes. The default code for
User 1 is ‘1111’. This default value must be changed immediately to prevent
unauthorized access to your system.

To program user codes 1-4:
1. Press 

Q

5

.

2. Enter User Code 1; the Armed and System LEDs flash and the zone LEDs indicate

the programming status of each user code as follows:

 

OFF:

NOT PROGRAMMED

 

ON:

PROGRAMMED

 

FLASHING:

CURRENTLY BEING PROGRAMMED

3. Enter the number of the code to be changed (1-4); the requested zone LED flashes.
4. Enter the new user code; the LED stops flashing.

Note: If the new code is identical to an existing user code, an error tone will be
sounded and the new code will not be accepted.

To erase a user code:
1. Press 

Q

5

.

2. Enter User Code 1.
3. Enter the number of the code to be erased (1-4); the requested zone LED flashes.
4. Enter  

Q

Q

Q

Q

; the LED stops flashing and the code is erased.

Note: Do not erase User Code 1! Erasing this code denies the user the ability to
program user codes. If User Code 1 is accidentally erased,contact your installer.

Summary of Contents for Penta

Page 1: ......

Page 2: ...planation you will receive from your installer we urge you to read through this manual This will help you familiarize yourself with the system so that you can take advantage of its many advanced features This booklet should be kept in an accessible location and the system reference guide located in the rear portion of this manual should be filled out If you do not understand any part of this manua...

Page 3: ...curity zones A zone can be defined as a protected area in your security system Each zone can be protected by one or more detection devices such as motion detectors magnetic contacts glassbreak detectors and shock sensors When one of these detection devices is activated it opens the zone to which it is connected System Monitoring Your security system can be monitored either by a monitoring service ...

Page 4: ...tem is ready to be armed SYSTEM The System LED blinks to indicate that new events have been recorded in one of the logs and when displaying additional system information such as bypass mode ARMED The Armed LED lights to indicate the system is armed or in programming mode and flashes during the exit delay POWER The Power LED lights up when both AC battery power are OK blinks when the battery is low...

Page 5: ...ystem operations such as arming and disarming Each user code is four digits long Of the four user codes only User Code 1 has the authorization to program other user codes The default code for User 1 is 1111 This default value must be changed immediately to prevent unauthorized access to your system To program user codes 1 4 1 Press Q 5 2 Enter User Code 1 the Armed and System LEDs flash and the zo...

Page 6: ...nes are still not secured after the exit delay has ended an alarm will be generated To force arm the system 1 Press Q 8 2 Enter a valid user code the keypad beeps until the end of the exit delay Quick Arming This feature allows you to arm the Penta without entering a valid user code To Quick arm the system 1 Check that all zones are closed the Ready LED lights up to indicate that the system is rea...

Page 7: ...ypassed the corresponding zone LED lights up 4 Press to exit bypass mode the bypassed zones flash To unbypass a zone 1 Press Q 1 2 Enter a valid user code the System LED flashes and the LEDs of any currently bypassed zones light up 3 Enter the number of the zone to be unbypassed the corresponding zone LED turns off 4 Press to exit bypass mode Note Disarming the system automatically unbypasses all ...

Page 8: ...Alarm event log 1 Press Q 3 an alarm from a specific zone is indicated by the corresponding zone LED 2 Press to exit the event log Both logs are automatically reset when the system is next armed 3 9 Follow me If your system is not monitored by a central station either the Follow me or Voice message feature is used to inform you that an alarm has occurred When using Follow me the Penta dials the te...

Page 9: ... of short beeps to indicate Zone Chime OFF Keypad Backlight On Off To toggle the backlight of any keypad On or Off Press and hold down for more than 2 seconds 3 11 Testing the System Electronics Line recommends that you test your system at least once a week Walk Test Walk test mode enables you to test peripheral detection devices such as PIR detectors and magnetic door contacts In this mode when a...

Page 10: ...__________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ __________...

Reviews: