6
sired value then adjust the Model FC Front panel span adjustment until it does.
I. A catch test can be run to verify the accuracy of the maximum flow rate of the Magna-
Valve. If necessary, Adjust the Pre-Amp span adjustment ( not the FC controller span
adjustment) and repeat the catch and weigh tests until the correct amount of shot is
caught. Adjust the span once at any desired flow rate for proper flow then fill in the
chart to check performance.
J. Confirm the accuracy by filling in the table column marked “Actual lbs/min” in the table
corresponding to the desired maximum flow rate. Correct discrepancies by making ad-
justments to the compensation trimpots as necessary.
The Tables are located at the end of this document.
4. Trouble shooting
For additional troubleshooting information see the model FC installation manual IM0056.
For assistance call or fax the factory for help
Phone 1-(574)-256-5001
FAX 1-(574)-256-5222
www.shotpeener.com
Summary of Contents for 250-N
Page 2: ...2 Wiring Diagram ...