EA KIT160-6
Digital In- and Outputs J120
Pin Symbol
Function
Pin Symbol
Function
1
VDD
+5V Supply
2
GND
0V, Ground
3
OUT 1
Output 1
4
IN 1
Input 1
5
OUT 2
Output 2
6
IN 2
Input 2
7
OUT 3
Output 3
8
IN 3
Input 3
9
OUT 4
Output 4
10
IN 4
Input 4
11
OUT 5
Output 5
12
IN 5
Input 5
13
OUT 6
Output 6
14
IN 6
Input 6
15
OUT 7
Output 7
16
IN 7
Input 7
17
OUT 8
Output 8
18
IN 8
Input 8
19
GND
0V, Ground
20
VDD
+5V Supply
Default settings
Register
Com m and
After
power-on/reset
Text mode
ESC L
Set, black
Terminal font
ESC FT
Font 3, no zoom
Cursor
ESC QC
On
Flashing time
ESC QZ
0.6 secs
User-defined characters
ESC E
Undefined
Graphics mode
ESC V
Set
Graphics font
ESC F
Font 3, no zoom
Last xy
ESC W
(0;0)
Bar graph 1..16
ESC B
Undefined
Clipboard
ESC C
Empty
Select/deselect
ESC K
Selected
Outputs OUT1..8
ESC Y
High level/open
INPUTS AND OUTPUTS
The EA KIT160 is supplied with 8 digital inputs and 8 outputs (5V CMOS level, non-isolated). The
connection is made at the 20-pin connector J120.
8 outputs: Each line can be controlled by means of the
„ESC Y W“ command. The maximum current per line
is 6mA. Output 8 (PIN 17) is used to switch the LED
backlighting (ESC Y L n1). If this output is required, the
LED backlighting can be separated from the output
via the solder strap LB 8 and switched on
permanently.
8 inputs: The inputs can be queried and evaluated
(„ESC Y R“) directly via the serial interface. Each
change of logic level (0V or 5V) at the inputs can start an internal port macro. When the 8 lines are
combined, 256 port macros can be addressed. Each of these port macros can change the contents of
the screen or switch an output. This allows a wide range of control tasks to be carried out. To create the
port macros, you need a PC and the floppy disk EA DISK240. You will find a more detailed description
of this on page 6. Automatic poll querying can be disabled by means of the „ESC Y A 0“ command.
Note: The logic circuitry is designed for slow operations; in other words, more than 3 changes per second
cannot be easily executed. If an input is open, this is evaluated as high (approx. 100 kOhm pullup).
Application examples:
DEFAULT SETTINGS
After power-on or a manual reset, the registers shown here
are set to a specific value.
Please note that all the settings can be overwritten by creating
a power-on macro (normal macro no. 0).