BEFORE USING THE TORQUE WRENCH 

 

Battery Installation 

 



Remove the battery cover 

 



Insert one (1) AAA batteries 
with positive end facing the 
front of the torque wrench 

 



Reinstall battery cover and 
rotate to lock it in place. 
Take care to line up arrows 
on cap and back of torque 
wrench when installing. 

 
 

POWER ON AND RESETTING 
THE TORQUE WRENCH 

 



Press 

C

 to power on the torque wrench 



Press 

C

 to zero the torque torque wrench before use 



NOTE

: After pressing 

C

 the target torque value will be displayed 

 

ATTENTION

1.  If an external force is applied to the torque wrench during power-on 

or zeroing an initial torque offset will exist in memory. 

2.  The measuring unit and operating mode (track / peak) are stored in 

memory. Once set they will be permanently stored. 

 
 

SLEEP MODE 

 

The torque wrench will automatically go to sleep after 5 minutes of non-
use. Press 

C

 to wake the torque wrench from sleep. 

 
 

INSTALLING SOCKET 
 

The DTL torque wrench uses standard 1/4” (6.35mm) 
sockets. To remove the socket press the release 
button on the top of the wrench head.

 

 

 

5

 

 

SELECTING UNITS OF MEASURE 

 

The DTL torque wrench can display measurements in Newton Meters 

(

N-m

), Pound-Inch (

lb-in

), Pound-Foot (

lb-ft)

 and Kilogram Centimeter 

(

Kg-cm)

. The selected measuring unit is displayed right side of the 

display. 

 

Press the 

U/S

 to switch between measuring units. 

 

SELECTING TRACK / PEAK MODE 

 

The DTL can display torque in 

TRACK 

or 

PEAK 

mode. When in 

track 

mode the torque wrench will display the target torque while there is no 

torque applied, when torque is applied the torque wrench will display 

real-time torque value until pressure is removed, then the display will 

show the target value. In peak mode the torque wrench will display the 

target torque while there is no pressure applied, when pressure is 

applied the torque wrench will display and hold the highest value 

measured until pressure is removed from the torque wrench then 

applied again or the 

C

 (zero) key is pressed. 

 

To select TRACK or PEAK mode press and hold the 

U/S 

key for 2 

seconds, the display will show 

MODE

, then press the up or down arrow 

key to select between PEAK or TRACK mode (indicated by a small P or 

T in the bottom right corner of the display). Then press the 

U/S 

key two 

times to confirm your selection and return to measurement mode.

 

 

SETTING TARGET TORQUE 

 

The DTL has 1 adjustable preset target value. The preset value is 

displayed on the screen after 

C

 is pressed. To adjust the preset press 

the UP / DOWN arrow keys to set the target value. The wrench saves 

both target torque and unit of measure when the torque wrench is 

powered off. 

 

 

 

Summary of Contents for DTL

Page 1: ...MATIC Equip t Co Inc 600 Oakland Ave Cedarhurst NY 11516 Tel 800 645 4330 516 295 4300 Web www CheckLine com Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web https www abqindustrial net E mail info abqindustrial net ...

Page 2: ...partment 600 Oakland Ave Cedarhurst NY 11516 Please visit www checkline com repair for complete instructions and services rates WARRANTY ELECTROMATIC Equip t Co Inc expressly warrants to its buyer for one 1 year from the date of delivery that the goods sold are free from defects in workmanship and materials ELECTROMATIC Equip t Co Inc will at its option repair or replace or refund the purchase pri...

Page 3: ... 7 If the torque wrench gets wet wipe it with a dry towel as soon as possible The saltwater can be especially damaging 8 Do not use organic solvents such as alcohol or paint thinner when cleaning the torque wrench 9 Keep this torque wrench away from magnets 10 Do not expose this torque wrench to dust or sand as this could cause serious damage 11 Do not apply excessive force to the LCD panel 3 SPEC...

Page 4: ...entimeter Kg cm The selected measuring unit is displayed right side of the display Press the U S to switch between measuring units SELECTING TRACK PEAK MODE The DTL can display torque in TRACK or PEAK mode When in track mode the torque wrench will display the target torque while there is no torque applied when torque is applied the torque wrench will display real time torque value until pressure i...