![Electrolux WTM165ERA User Manual Download Page 36](http://html.mh-extra.com/html/electrolux/wtm165era/wtm165era_user-manual_91272036.webp)
38
E7
Electrical connections
Connection to the power supply must be carried out in
conformity with the current regulations and provisions
in the country of use.
•
Make sure the machine power supply voltage spec-
ified on the rating plate (Table 1) matches the
mains voltage.
•
Make sure the system power supply is arranged
and able to take the actual current load and that it is
executed in a workmanlike manner according to the
regulations in force in the country of use.
To connect the power cable to the equipment, proceed
as follows:
-
remove the front panel of the machine, in which the
main switch is located;
-
connect the power cable to the main switch as indi-
cated in the wiring diagram attached to the
machine, and secure it with the special cable gland;
-
close the front panel of the machine.
E8
Installation of detergent/rinse aid dispensers
The machine is arranged for installation of detergent
and rinse aid dispensing devices.
The dispensers must be fitted in a way that does not
compromise machine operation or safety.
E8.1
Arrangement for water connection
Described below are all the possible plumbing connec-
tions that can be made in the machine for installing
detergent or rinse aid dispensing devices.
E8.1.1
Detergent concentration measurement
probe
For positioning the detergent concentration measure-
ment probe there is a hole “XP” (Ø 22 mm) closed with
a plug (Figure 9) in the wash tank, as already indicated
also in par. E6.2 “Installation diagrams”.
Figure 9 Hole for detergent probe
E8.1.2
Liquid detergent dispensers
Inside the wash tank there are two indents “XD” (Ø 5
mm) to be perforated for fitting a liquid detergent injec-
tor (Figure 10), as already indicated also in par. E6.2
“Installation diagrams”.
Figure 10 Arrangement for liquid detergent
IMPORTANT!
Work on the electrical systems must
only be carried out by a qualified electri-
cian.
IMPORTANT!
The connection cable must be H07RN-F
type, oilproof.
IMPORTANT!
All electrical interventions ahead of the
machine must be carried out by quali-
fied electricians and with the power to
the equipment being wired discon-
nected.
IMPORTANT!
Do not start the machine if the dis-
penser devices do not meet the safety
requirements of EC Directives or cur-
rent regulations in the country of use.
CAUTION!
Contact with chemical substances (e.g.
detergent, rinse aid, scale remover,
etc.) without taking appropriate safety
precautions (e.g. personal protection
equipment) can involve exposure to
chemical risk and possible damage to
health. Therefore always refer to the
safety cards and labels on the products
used.
CAUTION!
The use of "foaming"/non-specific
detergents or in any case detergents
used in different ways from that pre-
scribed by the manufacturer, can cause
damage to the dishwasher and com-
promise washing results.
IMPORTANT!
Carry out all the following plumbing
connections with particular care, in
order to avoid any leaks of liquid inside
the machine and near the electrical
connections.
IMPORTANT!
Faulty plumbing connections can
cause low machine performance due to
pressure losses in the system.
XP
XD
XD