DOC. NO. 5956.573.05
P. 83 / 88
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
G FLOWCHARTS FOR TROUBLESHOOTING
(*)
If CoM Err1 appears among the communication alarms,
correctly set parameter "Apt".
Correctly insert it or replace if neces-
sar
Correctly insert them or replace if the contact
is open.
Check the values of parameter "Apt" as indi-
cated in par. A.4.1.2. Generic.Func.
Make sure connector X6
and relevant jumpers (see
Layout 5/ 6/ 7 - page 68, 69
and 70) are properly insert-
ed in the respective MEC's.
NO
NO
NO
YES
YES
CoM Err 2 or CoM Err 3 or CoM Err 2 - 4 or CoM Err 2 - 3 - 4 or CoM Err 3 - 4 alarm (*)
START
Replace User A1.
Check the correct power supply
230V (-15% ; +10%) on board
AP1 between connector X1
(contact 3) and connector X3
(contact 1).
NO
YES
Check the wiring between connector X3 of
AP1 and connector X21 of AP1 (also check
the respective through-wall fitting XC2) and
repair/replace the damaged component if
necessary.
Check the correct power supply
230V (-15% ; +10%) on User
card A1 on connector J21 (con-
tacts 1 and 4).
NO
YES
Replace the User AP1.
Check the correct power supply
230V (-15%; +10%) on board
AP1 in connector J26 (contacts
1 and 2).
NO
YES
YES
Continued on the next page.
Check the continuity of the bus
communication cable and that
it is properly inserted between
the User card and the various
MEC's (see communication ca-
ble and bus cable path).
Make sure the parameter "Apt"
is correctly set according to the
type of machine.
COMPACT SHORT