WARNING:
If an alarm relevant to the gear motor (27-76-77) is in progress, a door is opened or the emergency
stop is activated, gear motor setting is not carried out and the display shows.
If none of the above events occurs, gear motor setting is carried out with the following criteria:
the gear motor is made to operate at all the speeds provided for and the absorbed current is measured for
each speed. The measured value is added to the value of the “Mot. curr. margin” (
) parameter
(“GENERIC FUNC” family) and the value thus obtained is saved and associated with the corresponding speed.
A table is thus created where each speed is associated with the corresponding max. current.
Example: if at 25 Hz the current measured = 33dec A and the “Mot. curr. margin” (
) parameter = 2decA,
in normal operation at the speed of 25 Hz, the max. current that can be absorbed by the gear motor is 34
decA before shutting down the machine and showing the message:
The value of theo “Mot. curr. margin” (
) parameter makes the machine more or less sensitive to possible
jamming.
WARNING:
Do not modify the “Mot. curr. margin” (
) parameter unless expressly requested by the factory.
During the setting procedure, which lasts approx. 3 minutes, the display shows the following screen:
At the end of the current setting procedure the display shows the following screen:
GEARMOTOR SET-UP
NOT EXECUTED
PRESS TO EXIT
mot
AdJ
n_d
sEE
itE
ins
GEARMOTOR SET-UP
IN PROGRESS
GEARMOTOR SET-UP
Mot
AdJ
prG
GEARMOTOR SET-UP
DONE
PRESS TO EXIT
Mot
AdJ
EnD