background image

Electrolux Dishwashing

Glasswashers WT2

Internet: http://www.electrolux.com/foodservice

IAB010

2011-05-16

Subject to change without notice

EI - Electrical connection

230 V, 1N, 60

230 V, 1N, 50

400 V, 3N, 50

230 V, 1N, 50

230 V, 1N, 50

230 V, 1N, 50

D - Water drain

27mm

27mm

27mm

22mm

27mm

27mm

CWI - Cold water inlet

G 3/4"

G 3/4"

G 3/4"

G 3/4"

G 3/4"

G 3/4"

LEGEND

WT2TOP60

402015

WT2WSDPD

402032

WT2DPD3

402067

WT2DPDI

402016

WT2WSDPDI

402017

WT2TOPDI

402019

402015, 402019, 402017, 402016, 402067, 402032

Summary of Contents for WT2

Page 1: ...th surfaces and a fully pressed wash tank with rounded corners to facilitate cleaning All the internal elements arms and filter are easily extractable 304 AISI stainless steel front and side panels load bearing frame wash tank tank filter and wash and rinse arms EASY TO USE Built in rinse water heater to increase the temperature of the final rinse water Built in rinse aid dispenser for perfect rin...

Page 2: ...y lt 6 6 6 6 6 6 6 6 6 6 6 temperature C 55 65 55 65 55 65 55 65 55 65 55 65 55 65 55 65 55 65 55 65 55 65 Washing cycle height 290 290 290 290 290 290 290 290 290 290 290 depth 400 400 400 400 400 400 400 400 400 400 400 width 400 400 400 400 400 400 400 400 400 400 400 Cell dimensions mm height 715 715 715 715 715 715 715 715 715 715 715 depth 565 565 565 565 565 565 565 565 565 565 565 width 46...

Page 3: ...867061 867061 867061 867061 867061 867061 867061 867061 867061 867061 867061 FILTER FOR TOTAL DEMINERALIZATION 864015 864015 864015 864015 864015 864015 FILTER FOR PARTIAL DEMINERALIZATION 864017 864017 864017 864017 864017 864017 COVER GRID FOR SMALL LIGHT ITEMS IN RACK 867016 867016 867016 867016 867016 867016 867016 867016 867016 867016 867016 BASKET FOR GLASSES 395X395X200 MM 867054 867054 867...

Page 4: ...ternet http www electrolux com foodservice IAB010 2011 05 16 Subject to change without notice EI Electrical connection 230 V 1N 50 230 V 1N 50 D Water drain 22mm 22mm CWI Cold water inlet G 3 4 G 3 4 LEGEND WT2 402061 WT2N 402035 402061 402035 ...

Page 5: ...ux com foodservice IAB010 2011 05 16 Subject to change without notice EI Electrical connection 400 V 3N 50 230 V 1N 50 230 V 1N 50 D Water drain 27mm 27mm 27mm CWI Cold water inlet G 3 4 G 3 4 G 3 4 LEGEND WT2N4 402047 WT2TOP 402044 WT2WSDP 402030 402047 402030 402044 ...

Page 6: ... Electrical connection 230 V 1N 60 230 V 1N 50 400 V 3N 50 230 V 1N 50 230 V 1N 50 230 V 1N 50 D Water drain 27mm 27mm 27mm 22mm 27mm 27mm CWI Cold water inlet G 3 4 G 3 4 G 3 4 G 3 4 G 3 4 G 3 4 LEGEND WT2TOP60 402015 WT2WSDPD 402032 WT2DPD3 402067 WT2DPDI 402016 WT2WSDPDI 402017 WT2TOPDI 402019 402015 402019 402017 402016 402067 402032 ...