5. Diagnosis
Mode
Activation
and
deactivation
by simultaneously activating the four buttons for the adjustment
of the target values (min. 3 sec.) . When the diagnosis mode is active, "t
E
“ alternates with the
ACTUAL temperature of the top sensor in the left-hand display and in the right-hand display,
the ACTUAL temperature of the top sensor alternates with the consumer status.
The temperature displays in Diagnosis Mode are not the average compartment temperatures
but the ACTUAL temperature at the sensor position.
The following functions are possible.
Compressor on / off
"
+"
cold compartment
Display CI / CO
Heating
on / off
"
- "
cold compartment
Display HI / HO
The heating function is reset to "off" after 10 minutes for safety reasons.
Flap
open / closed "
+"
cold compartment Display SI / SO
Ventilator
on / off
"
- "
cold compartment
Display LI / LO
The Diagnosis Mode is automatically deactivated after 30 minutes for safety reasons.
The Diagnosis Mode can be deactivated at all times by switching the main switch off.
Presentation Mode
An operation mode is possible for presentations, by which the compressor, ventilator, heating
and air flap are not switched.
The Presentation Mode is
activated
and
deactivated
by simultaneously pressing the button
combination
Target Value Adjustment"+" top, "Supercool" and target Value Adjustment
"+" bottom
(min. 3 sec.)
"
dE"
is briefly displayed in the left-hand display after activation, "
dA
“ being briefly displayed
in the left-hand display after deactivation.
The target value adjustment, lighting, door switch and the door alarm remain active. The
"Supercool" function button only switches the LED but does not switch the compressor
on
and
off.
The target values are shown in the right-hand and left-hand display as ACTUAL values.
In order to control the "Presentation Mode" operating mode, the "Supercool" LED briefly
illuminates every 5 seconds or it is briefly extinguished if the "Supercool" is activated.
A switching off and on by means of the main switch or a power failure does not result in a
deactivation of the Presentation Mode.