23
23. Programme unit
24
438 9149-81/06
04.03
Service
Manual
Super imbalance measurement
Super imbalance measurement is the normal imbalance measurement. Its
task is to ensure that the machine is not overloaded during extraction, as
well as to ensure that the number of missed extractions is as small as
possible.
Super imbalance measurement starts a few seconds after the drum has
reached distribution rpm. The delay is there to allow the motor rpm to
Ôsettle down’ so that it is as stable as possible.
The magnitude of the imbalance is measured and compared first with a
fairly low imbalance limit value 1. If the imbalance exceeds this limit value,
the drum is slowed down to a lower rpm in order to achieve redistribution of
the clothes. It then accelerates again without stopping at the distribution
rpm again, after which a new imbalance measurement is carried out. The
number of attempts at limit value 1 may be set in the system data and can
also be altered in configuration 2. The value is normally set at 3.
If the imbalance is below the limit value, extraction starts at the extraction
speed specified in the programme after the distribution time has elapsed.
If the imbalance still does not drop below limit value 1 after three attempts,
the imbalance is instead compared with a slightly higher permitted
imbalance value, limit value 2. If the imbalance exceeds this limit value, the
drum is slowed down to a lower rpm in order to achieve redistribution of the
clothes. It then accelerates again without stopping at the distribution rpm
again, after which a new imbalance measurement is carried out. The
number of attempts at limit value 2 may be set in the system data and can
also be altered in configuration 2. The value is normally set at 2.
If the imbalance is suddenly lower than one of the two limit values, the
extraction starts with the extraction speed programmed in the programme.
The reason for the use of two limit values, both of which produce the same
extraction rpm, is that in order to look after the machine’s mechanism, it is
desirable in the first instance to extract with as low an imbalance as
possible.
In the same way as above, the imbalance is compared with a further two
limit values, limit value 3 and limit value 4. However, each of these gives a
reduced extraction rpm if the imbalance is below the limit value. The
number of attempts at limit values 3 and 4 may be set in the system data
and can also be altered in configuration 2. The value for each is normally
set at 2.
Summary of Contents for W3105H
Page 1: ...Service Manual W365H W375H W3105H W3130H W3180H W3240H W3300H Exacta 438 9201 81 EN 06 42 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 23: ...11 Regular maintenance 438 9145 01 01 00 23 Contents Daily 3 Every third month 3 ...
Page 24: ......
Page 28: ......
Page 66: ......
Page 74: ......
Page 76: ......
Page 100: ......
Page 102: ......
Page 122: ......
Page 142: ......
Page 144: ......
Page 148: ......
Page 149: ...39 Detergent compartment 438 9146 21 01 00 23 Contents Description 3 ...
Page 150: ......
Page 152: ......
Page 154: ......
Page 158: ......
Page 160: ......
Page 164: ......
Page 165: ...43 Frame 438 9146 61 01 00 23 Contents Description 3 ...
Page 166: ......
Page 168: ......
Page 169: ......
Page 170: ...www electrolux com professional Share more of our thinking at www electrolux com ...