4. Replace X3. Remove the contactor X312 and
measure the resistance of the contactor with
the motor cabling between X312:4 - 5.
Contact
Interruption
Defective cabling
between motor
controller and motor.
Inspect the cabling and
replace if necessary.
Internal error in the thermal sensor of the motor
controller detector.
5. Switch of the wall-mounted power switch. Undo the
contactor at X3 on the motor. Use an ohm meter to
measure the resistance towards the motor. Measure
between 1-2, 1-3 and 2-3.
Resistance
W365H
4 ohm
W375H
4 ohm
W3105H
4 ohm
W3130H
2 ohm
W3180H
1,2 ohm
W3240H
0,8 ohm
W3300H
0,8 ohm
Correct resistance
One of the resistance
values is incorrect
The motor is probably
defective.
Troubleshoot the cabling between the motor and motor
controller.
32
3402
31
5181
X312
Fig.
31
Fig.
32
1
Contactor X3, female towards motor
Measure resistance between pins 1, 2 and 3
3
Summary of Contents for W3105H
Page 1: ...Service Manual W365H W375H W3105H W3130H W3180H W3240H W3300H Exacta 438 9201 81 EN 06 42 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 23: ...11 Regular maintenance 438 9145 01 01 00 23 Contents Daily 3 Every third month 3 ...
Page 24: ......
Page 28: ......
Page 66: ......
Page 74: ......
Page 76: ......
Page 100: ......
Page 102: ......
Page 122: ......
Page 142: ......
Page 144: ......
Page 148: ......
Page 149: ...39 Detergent compartment 438 9146 21 01 00 23 Contents Description 3 ...
Page 150: ......
Page 152: ......
Page 154: ......
Page 158: ......
Page 160: ......
Page 164: ......
Page 165: ...43 Frame 438 9146 61 01 00 23 Contents Description 3 ...
Page 166: ......
Page 168: ......
Page 169: ......
Page 170: ...www electrolux com professional Share more of our thinking at www electrolux com ...