background image

1 9

A.2.1 MATERIALS AND FLUIDS USED

Areas in contact with the product are manufactured in steel or
coated with non-toxic plastic material. An HFC refrigerant in
compliance with current regulations is used in the refrigerating
units. The type of refrigerant gas used is given on the data plate.

A.2.2 DIMENSIONS, PERFORMANCE AND CONSUMPTION

"V160" FREESTANDING FREEZER AND REFRIGERATED
COUNTERS

Gross capacity

lt

160

External dimensions:
- width

mm

595

- depth with door open

mm

1167

- depth with door closed

mm

620

- height:

mm

855

Refrigerated cell dimensions:
- width

mm

482

- depth

mm

465

- height

mm

728

Dimensions of freezer cell:
- width

mm

429

- depth

mm

396

- height

mm

680

Racks provided:

2+1

Rack dimensions:
- rack attached to bottom - 

refrigerated table

mm

475 x 273

- adjustable racks - 

refrigerated table

mm

478 x 410

- rack attached to bottom - 

freezer table

mm

415 x 250

- adjustable racks - 

freezer table

mm

424 x 320

Refrigerated tables

Temp. range. in cell

°C

0/+10

Max. ambient temperature

°C

+38

Consumption

kwh/24h

1,73

Power supply voltage

V/ph/Hz

230/1/50

Max. current

A

0,5

Total power

W

73

Refrigerant capacity (R134a)

g.

55

Freezer tables

Temp. range. in cell

°C

-20/-15

Max. ambient temperature

°C

+38

Consumption

kwh/24h

1,66

Power supply voltage

V/ph/Hz

230/1/50

Max. current

A

0,62

Total power

W

82

Refrigerant capacity (R134a)

g.

100

"V170" REFRIGERATED UNDERCOUNTERS

Gross capacity

lt

170

External dimensions:
- width

mm

597

- depth with door open solid door model

mm

1155

- depth with door open glass door model

mm

1147

- depth with door closed

mm

607

- height:

mm

850

Compartment dimensions solid door model:
- width

mm

544

- height

mm

657

Compartment dimensions glass door model:
- width

mm

544

- depth

mm

470

- height

mm

657

Shelves supplied with all models

no.

2+1

A.1.1 FOREWORD

This manual is intended to provide the necessary information for
correct installation of the appliance. Therefore the manual and all
the technical documentation enclosed with the machine must
always stay with the equipment for possible consultation by
technicians and users. It is important for the user of the appliance
to know the regulations regarding safety during and after instal-
lation.
Carefully read the instructions in this manual before carrying out
any operation as they provide important information on the
regulations regarding safe installation and use of the appliance.

Incorrect installation, adjustment, modification, assistance
or maintenance can cause damage, injury or death. The
manufacturer declines any liability for operations carried
out on the appliance without following the instructions
given in this manual. The use of non-original parts relieves
the manufacturer of any warranty and liability.
No part of this manual may be reproduced.

A.1.2 INTENDED USE AND LIMITATIONS

This appliance is designed for the refrigeration and preservation
of food. Any other use is to be considered improper. Its use is
strictly limited to adult individuals.

CAUTION:

the appliances are not suitable for installation outdoors and/or in
places exposed to atmospheric agents (rain, direct sunlight, etc.).

The manufacturer declines any liability for improper use of
the products.

A.1.3 TESTING

Our equipment has been designed and optimised with laboratory
testing in order to offer high performance and efficiency. The
product is delivered ready for use.
Passing of the tests (visual inspection - electrical test - functional
test) is guaranteed and certified by means of the specific enclo-
sures (par. D.5).

A.1.4 GENERAL SAFETY RULES
Appliance construction complies with European Low Volt-
age Directives 73/23-93/68/EEC, electrical systems accord-
ing to Standards EN 60-335-1, EN 60-335-2-89 and Electro-
magnetic Compatibility according to Standards EN 55014-1;
EN 61000-6-1; EN 61000-6-3; (89/336/EEC); EN 55014-2, EN
50366.
Validity according to the latest current regulations.

A.1.5 CUSTOMER RESPONSIBILITIES

The customer must provide an earthed electricity socket of
suitable capacity for the absorption specified on the data plate.
Between the power cord and the electrical line there must be an
omni-polar differential switch, with high sensitivity  manual reset,
properly sized, realized in accordance with current standards. For
proper sizing of the switch, refer to the absorbed power as
indicted on the technical data plate of the appliance.
Check the flatness of the appliance support surface.

A.1.6 DATA PLATE POSITION

The data plate that includes all data for the appliance is located
on the right-hand side where there is the unit compartment, when
looking at the appliance from the rear.

In "V160" freestanding counters

 the plate giving the appliance

PNC code and serial number is located below the logo.

In "V170" undercounters

 the plate giving the appliance PNC

code and serial number is located above the thermostat inside,
whereas the plate giving the appliance technical data is located
on the right side of the unit compartment.

 A.1 GENERAL INFORMATION

GB

 A.2 TECHNICAL DATA

Summary of Contents for V160 series

Page 1: ... adjustment modification assistance or maintenance can cause damage injury or death The manufacturer declines any liability for operations carried out on the appliance without following the instructions given in this manual The use of non original parts relieves the manufacturer of any warranty and liability No part of this manual may be reproduced A 1 2 INTENDED USE AND LIMITATIONS This appliance...

Page 2: ...ion B 1 1CHECKS ON RECEIVING THE APPLIANCE The equipment is delivered in protective packing check the state of the packing and any protection materials before unpacking Any damage must be promptly reported to the carrier Under no circumstances should a damaged appliance be returned to the manufacturer without prior notice and written permission CAUTION the operations described below must be carrie...

Page 3: ...ch the equipment can operate is 38 C Adjust height and levelling by means of the levelling feet while at the same time checking the doors for proper closure Align the door with the side adjusting the hinge on the bottom of the appliance remove screw a from its seat b a and screw it in slot b providedontheedgeasshowninthefigure b b Now with the hinge loosened the door can be aligned After completin...

Page 4: ...eactivated OFF For especially harsh operating environments with ambient tem peratures higher than 32 C and high humidity it is advisable to set the thermostat between 1 and 4 In general it is advisable to set the knob to the intermediate position ADJUSTMENT OF TEMPERATURE IN FREEZERS Refer to paragraph D 1 B 1 5 ELECTRICAL CONNECTION Before undertaking any procedure involving electrical connec tio...

Page 5: ...for at least 5 seconds to start a manual defrost cycle This function is signalled by lighting up of the DEFROST LED If defrost conditions do not exist the display flashes three times to signal that the operation will not be carried out Defrosting cannot be started during the programming phase CAUTION Do not use spray defrost products on the freezers They can be harmful to the health and or they ma...

Page 6: ... signs of wear Have the equipment periodically checked at least once a year D 2 3 CELL CLEANING To clean the cell properly all of the racks must be removed They must therefore be removed from the cell before you start clean ing To extract them just pull them towards you you can put them back in afterwards by proceeding in the reverse manner Clean the cells with products that are more than 90 bio d...

Page 7: ...LING OF THE APPLIANCE Different regulations are in force in the various countries there fore the provisions laid down by the laws and the competent authorities in the countries where disposal takes place must be observed In general terms the refrigerator must be taken to a specialized collection demolitioncentre Dismantlethecomponentsandgroup them together according to their chemical characteristi...

Page 8: ...door closes properly 1 Make sure the plug is properly inserted in the power socket 2 Check that the socket is powered 1 Check the thermostat setting THE APPLIANCE DOES NOT SWITCH ON If the fault persists after having carried out the above checks contact Technical Assistance remembering to give the following details the nature of the fault the appliance PNC production code the Ser No appliance seri...