background image

2 1

The symbol 

L

 shown on the product means that it must 

not

 be

considered as domestic refuse, but rather must be disposed of
properly, in order to prevent any negative consequence for
individuals or the environment.
For further information concerning the recycling of this product,
contact the product’s local retailer agent, after sales technical
service or the local authority for waste disposal.

B.1.3 POSITIONING
B.1.3.1 General instructions
Install the equipment, taking all the safety precautions re-
quired for this type of operation, also respecting the relative
fire-prevention instructions.

Place the appliance in a well-ventilated place, away from heat
sources such as radiators or air-conditioning systems, in order to
allow correct cooling of the refrigerating unit components. Insuf-
ficient ventilation will in fact damage the appliance and prevent it
from working properly. Also, if the temperature is very high, the
compressor will activate more frequently  and for longer periods
of time, resulting in higher consumption of electrical energy.
Keep the ventilation openings free of any sort of obstruction.
Never cover the condenser, even temporarily, as this may com-
promise its proper operation and therefore that of the appliance.
If the appliance is installed in rooms where there are corrosive
substances (chlorine, etc.), it is advisable to go over all the
stainless steel surfaces with a cloth soaked in paraffin oil to create
a protective film.
The equipment’s performance is guaranteed at an ambient
temperature of +38°C. In any case, the max. ambient tempera-
ture at which the equipment can operate is +38°C.
Adjust height and levelling by means of the levelling feet,

while at the same time checking the doors for proper closure.
Align the door with the side, adjusting the hinge on the bottom of
the appliance: remove screw

 "a"

 from its seat

b

a

and screw it in slot 

"b"

 provided on the edge as shown in the figure

b

b

Now, with the hinge loosened, the door can be aligned.
After completing the operation, tighten the screw.

Make sure the floor on which the appliance stands is perfectly
level, in order to ensure its optimal operation.

 CAUTION:

the appliance must be level, otherwise its operation could be
compromised.

 CAUTION:

wait at least 2 hours before starting the appliance to allow the oil
to flow back into the compressor.

B.1.3.2 Instructions for "V170" undercounters

For positioning "V170" undercounters under a worktop, proceed
as follows:
• undo the screws fixing the top to the appliance, located at the

back;

• slide the top outwards a little to release it from the stops and

remove it from its seat;

• undo the screws fixing the rear feet  to the appliance;
• remove the 3 mm spacer from the feet and reposition them in

their seats;

• lastly, fit the front feet and adjust them until the appliance is at

the required height.

- ADJUSTMENT OF TEMPERATURE IN REFRIGERATED
APPLIANCES:

Turn the knob of the thermostat to “6”, “1” or any position in
between.

0

6

The thermostat knob is located at the upper right and is used to
set the temperature at which you wish the appliance to work. The
most suitable operating temperature needs to be selected in light
of the following factors:
• the ambient temperature in which the appliance operates;
• how often the door is opened;
• the amount of food stored;
• the position of the appliance with respect to the setting where

it is installed.

Summary of Contents for V160 series

Page 1: ... adjustment modification assistance or maintenance can cause damage injury or death The manufacturer declines any liability for operations carried out on the appliance without following the instructions given in this manual The use of non original parts relieves the manufacturer of any warranty and liability No part of this manual may be reproduced A 1 2 INTENDED USE AND LIMITATIONS This appliance...

Page 2: ...ion B 1 1CHECKS ON RECEIVING THE APPLIANCE The equipment is delivered in protective packing check the state of the packing and any protection materials before unpacking Any damage must be promptly reported to the carrier Under no circumstances should a damaged appliance be returned to the manufacturer without prior notice and written permission CAUTION the operations described below must be carrie...

Page 3: ...ch the equipment can operate is 38 C Adjust height and levelling by means of the levelling feet while at the same time checking the doors for proper closure Align the door with the side adjusting the hinge on the bottom of the appliance remove screw a from its seat b a and screw it in slot b providedontheedgeasshowninthefigure b b Now with the hinge loosened the door can be aligned After completin...

Page 4: ...eactivated OFF For especially harsh operating environments with ambient tem peratures higher than 32 C and high humidity it is advisable to set the thermostat between 1 and 4 In general it is advisable to set the knob to the intermediate position ADJUSTMENT OF TEMPERATURE IN FREEZERS Refer to paragraph D 1 B 1 5 ELECTRICAL CONNECTION Before undertaking any procedure involving electrical connec tio...

Page 5: ...for at least 5 seconds to start a manual defrost cycle This function is signalled by lighting up of the DEFROST LED If defrost conditions do not exist the display flashes three times to signal that the operation will not be carried out Defrosting cannot be started during the programming phase CAUTION Do not use spray defrost products on the freezers They can be harmful to the health and or they ma...

Page 6: ... signs of wear Have the equipment periodically checked at least once a year D 2 3 CELL CLEANING To clean the cell properly all of the racks must be removed They must therefore be removed from the cell before you start clean ing To extract them just pull them towards you you can put them back in afterwards by proceeding in the reverse manner Clean the cells with products that are more than 90 bio d...

Page 7: ...LING OF THE APPLIANCE Different regulations are in force in the various countries there fore the provisions laid down by the laws and the competent authorities in the countries where disposal takes place must be observed In general terms the refrigerator must be taken to a specialized collection demolitioncentre Dismantlethecomponentsandgroup them together according to their chemical characteristi...

Page 8: ...door closes properly 1 Make sure the plug is properly inserted in the power socket 2 Check that the socket is powered 1 Check the thermostat setting THE APPLIANCE DOES NOT SWITCH ON If the fault persists after having carried out the above checks contact Technical Assistance remembering to give the following details the nature of the fault the appliance PNC production code the Ser No appliance seri...

Reviews: