Installation manual
11
3.1.2
Technical data
Weight, net
kg
202
Drum volume
liters
255
Drum diameter
mm
755
Drum depth
mm
595
Drum speed, medium load
rpm
43
Rated capacity, filling factor 1:18 (Max. load)
kg
14.2
Rated capacity, filling factor 1:22 (Recommended load)
kg
11.6
Heating: Electricity
kW
6.0
kW
9.0
kW
13.2
kW
13.5
Optimum air flow, 6.0 kW**
m
3
/h
250
Optimum air flow, 9.0 kW**
m
3
/h
250
Optimum air flow, 13.5 kW**
m
3
/h
460
Optimum static back pressure, 6.0 kW**
Pa
710
Maximum static back pressure, 6.0 kW**
Pa
715
Optimum static back pressure, 9.0 kW**
Pa
710
Maximum static back pressure, 9.0 kW**
Pa
715
Optimum static back pressure, 13.5 kW**
Pa
550
Maximum static back pressure, 13.5 kW**
Pa
570
Sound power/pressure level at drying*
dB(A)
72/56
Heat emission of installed power, max
%
15
* Sound power levels measured according to ISO 60704.
** In a cold empty machine.
Connections
Air outlet
⌀
mm