Service Manual
65
Remove the screws and remove the outer sealing plate.
fig.7902
Cut loose the rear sealing from the inner sealing plate.
Put glue on the inner sealing plate and fasten the new rear sealing on the inner sealing plate. The rough side shall be
fastened to the glue.
fig.7903
Remount the outer sealing plate and fasten the screws.
Remount the RMC with arm.
Fasten the bolt and the washer and remount the bearing house. Use tightening torque 20 Nm ± 3 Nm.
On machines with RMC; pull the RMC flange back in position and tighten the screw. Use tightening torque 5 Nm ±
0.5 Nm.
Fasten the belt and make sure the belt is in position. Fasten the belt tensioner.
Remount the rear panel and the top panel.
Summary of Contents for T5350