27
On machines without reversing
Disconnect the power to the machine.
Demount the rear panel.
Disconnect the motor cable (A).
Loosen the belt tensioner (B).
Loosen both of the belts (C).
Demount the fan module.
7875
Demount the screw and pull off the fan wheel.
fig.7874
Mount the new fan wheel on the fan motor. Lubricate the screw using a protection product such as Omnifit Seal 40M
or similar and tighten the screw with tightening torque 5 Nm.
Remount the fan module in the machine.
Fasten the belts and make sure the belts are in position. Fasten the belt tensioner and connect the motor cable.
Remount the rear panel.