Carefully lift out the drum. When mounting the new drum, first fasten the belt temporarely on the drum, then put the
drum in position
fig.8045
Remount the drum.
Remount the supporting rail.
Remount the control panel.
Remount the RMC with arm.
Fasten the bolt and the washer and remount the bearing house. Use tightening torque 20 Nm ± 3 Nm.
On machines with RMC; pull the RMC flange back in position and tighten the screw. Use tightening torque 5 Nm ±
0.5 Nm.
Fasten the belt and make sure the belt is in position.
Remount the RMC with arm above the drum.
Remount the rear panel and the top panel.
Connect the door switch cable and remount the front panel.
Remount the filter.
Remount the door.