23:3 NO INTERLOCK
This error code is generated by the MCU for drum motor.
The MCU must be powered with 230V / 50 or 60 Hz on the interlock input in order to drive the motor. This signal is a
confirmation that the door is closed and locked.
MCU receives its commands to rotate the drum from the CPU via a serial communication link between the MCU and
CPU. Since the CPU also has access to the interlock signal, the CPU must never send a run command to the MCU if
the interlock signal is missing. If this does happen, this error code will be shown.
Possible causes:
The cause of this error code being activated can be e.g. a break in the cable leading the interlock signal to the MCU.
There may also be an error in the connector in the door lock, which connects 230V / 50 Hz to the interlock signal. An
error in the interlock circuits of the MCU can also set this error code.
Recommended actions:
1. Use a multimeter to check that there is 230V present on the MCU Interlock input when the door lock is activated.
Read also bit 1 in the second byte under
MCU STATUS
in the service program (the bits are numbered from 0 to 7
where bit 0 is on the far right). If bit 1 in the second byte is 1 then the lock is open, while a 0 indicates that the lock
is closed.
2. Replace the defective part.
23:4 NO COMMUNICATION
This error code is generated by the MCU for drum motor.
MCU detects there is there is a problem in communication with CPU.
Possible causes:
Bad contact in harness or connectors between CPU and MCU.
Recommended actions:
1. Check wiring, connections between CPU and MCU.
23:5 MOTOR SHORT CIRCIUT
This error code is generated by the MCU for drum motor.
The MCU reads the power consumption of the motor continuously. If the current for some reason exceeds a prede-
termined limit, the MCU will cut the current to the motor, and the error code will be shown.
Possible causes:
This error code can be activated for a number of reasons:
• Short circuit in motor. Measure motor windings with a Motor Tester.
• Short circuit internally in motor winding (impaired efficiency, higher current consumption).
• Short circuit in motor cables.
• Short circuit in connectors.
• Drops of water causing short circuits in the motor connector.
• Short circuit in the MCU output transistors.
• Bad contact in interlock signal.
Recommended actions:
1. If the error is a stable one, it is generally not difficult to locate the defective unit through resistance measurement
and testing with the service program. Measure motor windings with a Motor Tester.
2. Further information can be obtained by studying the contents of
MCU ERROR LOG 1
and
MCU ERROR LOG 2
.
3. Review following:
4.
SHORT CIRCUIT 1
(specifies how many times the current limit has been exceeded.
Summary of Contents for T5190LE
Page 2: ......
Page 30: ...30 Service Manual Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Page 35: ...Service Manual 35 Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Page 40: ...40 Service Manual Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Page 45: ...Service Manual 45 Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Page 117: ......