Electrolux RM 6501 Manual Download Page 8

The flue gases are dispersed through the upper vent
grille or the roof vent together with the ventilation air. 
The top, bottom and sides of the ventilation passage
should be insulated to prevent condensation and cold
draughts.

Ventilation heights

                               Minimum ventilation heights in mm.

 Model                                     Installation with

                          Upper side vent L205     Upper side vent L500     Roof vent R500

                          Lower side vent L500     Lower side vent L500     Lower side vent L500

 RM 6501            1400                     1400                       1250

LP GAS CONNECTION

The refrigerator is designed for operation on LP gas, the
pressure of which must be 28 mbar for Butane and 37 mbar
for Propane. Check that this is stated on the data plate.

The refrigerator is not designed for operation on
town gas or natural gas.

CAUTION! CHECK THAT THE GAS SUPPLIED
TO THE REFRIGERATOR IS AT THE CORRECT
PRESSURE. SEE THE REDUCING VALVE ON
THE LP GAS CONTAINER.

The gas installation should only be carried out by a
person experienced in gas fitting. It is recommended that
the gas pipe feeding the refrigerator is so arranged that
it is possible to turn off the supply of the refrigerator.

VENTILATION OF THE UNIT

min. ventilation
height

min. 510

Condenser

20

40

385

60

FIG. 3a

Sealing gasket
e.g. of V-type

Batten
attached to
the floor

Sealing gasket
e.g. of V-type

This piece is
already on the
refrigerator

Cut out opening for the
side vent L500
is 341 x 451 mm

Floor

Cut out opening for the
side vent L500
is 341 x 451 mm.

L205 is 156 x 451 mm.

min. ventilation
height

min. 510

Condenser

FIG. 3b

Cut out opening for the
side vent L500
is 341 x 451 mm

Cut out opening for the
roof vent R500
is 87 x 507 mm

Door

20

FIG. 3c

Batten attached
to the side wall

Sealing gasket
e.g. of V-type

View from above

16

Summary of Contents for RM 6501

Page 1: ...822 70 90 02 RA RM 2D 0402 RM 6501 MANUAL CARAVAN Español pagina 35 Deutsch Seite 3 English page 11 Svenska sida 27 Français page 19 Suomi sivu 44 ...

Page 2: ......

Page 3: ...erator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The data plate contains e g the following details Model designation RM Product number Serial number Voltage volts Gas pressure mbar Since these details will be needed if you have to contact service personnel it is a good idea to make a note of them here CONTENTS OPERATING I...

Page 4: ... to activate the flame failure device then release it If the lamp start flashing again repeat step 4 6 To terminate gas operation turn the knob A to OFF position 230 240 V operation Before operating the refrigerator check that the voltage stated on the data plate is the same as the main voltage in use Turn the thermostat knob D to its highest coldest position Set the energy selector A to position ...

Page 5: ...of detergent But not the door gasket which should only be cleaned with soap and water and then thoroughly dried The cooling unit behind the refrigerator should be cleaned with a brush from time to time but make sure that the refrigerator is switched off when doing this HEATING CABLE During the summer months of high temperatures and humidity the metal frame between the freezer and fresh food compar...

Page 6: ...strong odour are well packed The ventilation openings are unobstructed The doors are secured by means of the both travel catches when the caravan is on the move SERVICE AND SPARE PARTS Service and spare parts are obtainable from your dealer or Electrolux consult the telephone directory INSTALLATION INSTRUCTIONS REPOSITIONING THE HINGES The refrigerator is equipped with reversible doors A special d...

Page 7: ...ith the refrigerator in place drive the screws through the lining of the refrigerator into the walls of the enclosure There must not be more than 3 mm of clearance be tween refrigerator and enclosure on each side If neces sary wooden strips or similar should be fitted Note This is the only approved means of securing the refrigerator to the enclosure and to the vehicle Fasteners penetrating other p...

Page 8: ...LIED TO THE REFRIGERATOR IS AT THE CORRECT PRESSURE SEE THE REDUCING VALVE ON THE LP GAS CONTAINER The gas installation should only be carried out by a person experienced in gas fitting It is recommended that the gas pipe feeding the refrigerator is so arranged that it is possible to turn off the supply of the refrigerator VENTILATION OF THE UNIT min ventilation height min 510 Condenser 20 40 385 ...

Page 9: ...nd Yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured Green or Green and Yellow the wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black the wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red WARNING THIS A...

Page 10: ...mm Depth incl cooling unit with door 545 mm without door 495 mm Recess dimensions Height 1248 mm Width 530 mm Depth 510 mm Capacity Gross 135 litres Net 124 5 litres frozen food compt 23 5 litres Weight without packaging 44 kg Electrical data Input 230 240 volt 220 watt 12 volt 175 watt Energy consumption in 24h 3 kWh LP gas data Input max 0 34 kW Energy consumption in 24h 300 g Cooling medium Amm...

Reviews: