The refrigerator is intended for installation in a caravan
or a motorhome, and the description relates to this
application.
The refrigerator must not be exposed to radiated heat
from hot objects.
Excessive heat irradiation impairs performance and
leads to increased energy consumption. For this reason
the refrigerator should be installed if possible not at the
entrance side of the vehicle - normally orientated south
and often with an awning which would impair the disper-
sion of heat and combustion gases from the ventilation
openings.
It is not a good practice to install the refrigerator so that
the vent openings are covered by the vehicle’s entrance
door when this is set open. This would reduce the
ventilation airflow to the cooling unit and reduce refrigera-
tion performance.

The enclosure

The refrigerator must be installed in a substantial
enclosure and must be level, the dimensions are shown
in TECHNICAL DATA.

The bottom of the enclosure must be horizontal and even
so that the refrigerator can be easily pushed into place.
It must be sturdy enough to carry the weight of the
refrigerator.

Battens must be installed at the bottom, sides and top
of the enclosure and fitted with sealing strips.
Slide in the refrigerator until it is flush with the front of
the recess. There must be 10-20 mm free space behind
the refrigerator

Six fasteners are fitted in plastic bushings in the side
walls of the refrigerator, fig. 2. They are used for securing
the refrigerator in the enclosure.

The side walls of the enclosure and/or any wooden
braces installed to hold the refrigerator must be dimen-
sioned to seat the screws securely, also considering the
forces due to the movement of the vehicle.

With the refrigerator in place, drive the screws through
the lining of the refrigerator into the walls of the enclosure.
There must not be more than 3 mm of clearance be-
tween refrigerator and enclosure on each side. If neces-
sary, wooden strips or similar should be fitted.

Note: This is the only approved means of securing the
refrigerator to the enclosure and to the vehicle. Fasteners
penetrating other parts of the insulation (PU) foam of the
refrigerator might damage components like electric
wiring etc.

VENTILATION OF THE UNIT

At high ambient temperatures the refrigeration unit will
only perform adequately when properly ventilated.

Side ventilation.

The refrigerator unit is ventilated via two openings in the
wall of the caravan (fig. 3a).
Fresh air enters through the lower opening and warm air
is discharged through the upper one.
The lower opening should be located at floor level (to
allow any leaking gas to escape to the outside).

The upper ventilation opening should be located above
the condenser, as high as possible, to ensure good
ventilation.

Roof ventilation

The ventilation of the cooling unit can also be done via
one opening in the wall of the caravan and one on the
roof for the roof vent (fig. 3 b).
Fresh air enters through the lower opening and warm air
is discharged through the roof vent.

Ventilation grilles

We recommend fitting 2 side vents, model L500
alternative one L500 and one roof vent model R500,
which are specially developed by Electrolux for this
purpose.
The L500-ventilation grilles permit inspection and small
repairs to be carried out without the necessity to remove
the refrigerator from the recess.

Removal of flue gases

The ventilation passage at the rear of the recess, be-
tween the outer wall of the vehicle and the refrigerator
(fig. 3a/b/c), must be sealed off against the living space,
so cold draughts are excluded (winter camping) and no
flue gases can penetrate into the vehicle.

FIG. 2

15

Summary of Contents for RM 6501

Page 1: ...822 70 90 02 RA RM 2D 0402 RM 6501 MANUAL CARAVAN Español pagina 35 Deutsch Seite 3 English page 11 Svenska sida 27 Français page 19 Suomi sivu 44 ...

Page 2: ......

Page 3: ...erator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The data plate contains e g the following details Model designation RM Product number Serial number Voltage volts Gas pressure mbar Since these details will be needed if you have to contact service personnel it is a good idea to make a note of them here CONTENTS OPERATING I...

Page 4: ... to activate the flame failure device then release it If the lamp start flashing again repeat step 4 6 To terminate gas operation turn the knob A to OFF position 230 240 V operation Before operating the refrigerator check that the voltage stated on the data plate is the same as the main voltage in use Turn the thermostat knob D to its highest coldest position Set the energy selector A to position ...

Page 5: ...of detergent But not the door gasket which should only be cleaned with soap and water and then thoroughly dried The cooling unit behind the refrigerator should be cleaned with a brush from time to time but make sure that the refrigerator is switched off when doing this HEATING CABLE During the summer months of high temperatures and humidity the metal frame between the freezer and fresh food compar...

Page 6: ...strong odour are well packed The ventilation openings are unobstructed The doors are secured by means of the both travel catches when the caravan is on the move SERVICE AND SPARE PARTS Service and spare parts are obtainable from your dealer or Electrolux consult the telephone directory INSTALLATION INSTRUCTIONS REPOSITIONING THE HINGES The refrigerator is equipped with reversible doors A special d...

Page 7: ...ith the refrigerator in place drive the screws through the lining of the refrigerator into the walls of the enclosure There must not be more than 3 mm of clearance be tween refrigerator and enclosure on each side If neces sary wooden strips or similar should be fitted Note This is the only approved means of securing the refrigerator to the enclosure and to the vehicle Fasteners penetrating other p...

Page 8: ...LIED TO THE REFRIGERATOR IS AT THE CORRECT PRESSURE SEE THE REDUCING VALVE ON THE LP GAS CONTAINER The gas installation should only be carried out by a person experienced in gas fitting It is recommended that the gas pipe feeding the refrigerator is so arranged that it is possible to turn off the supply of the refrigerator VENTILATION OF THE UNIT min ventilation height min 510 Condenser 20 40 385 ...

Page 9: ...nd Yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured Green or Green and Yellow the wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black the wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red WARNING THIS A...

Page 10: ...mm Depth incl cooling unit with door 545 mm without door 495 mm Recess dimensions Height 1248 mm Width 530 mm Depth 510 mm Capacity Gross 135 litres Net 124 5 litres frozen food compt 23 5 litres Weight without packaging 44 kg Electrical data Input 230 240 volt 220 watt 12 volt 175 watt Energy consumption in 24h 3 kWh LP gas data Input max 0 34 kW Energy consumption in 24h 300 g Cooling medium Amm...

Reviews: