Electrolux RM 4180 User Manual Download Page 5

2. The evaporator is frosted up.

3. The temperature control setting is incorrect.

4. The gas pressure is incorrect - check the pressure regu-

lator at the gas container.

5. The ambient temperature is too high.

6. To much food is loaded at one time.

7 . The door is not properly closed or the magnetic sealing

strip is defective.

8. More than one source of energy is used at the same

time. If the refrigerator still does not work properly, call a
service technician.

MAINTENANCE

Concerning gas- and electric installations, only authorized
experts are allowed to carry out maintenance and repair
works. Besides, it is recommendable to contact an authori-
zed service if it comes to repair works.

According to the valid regulations G607 of DVGW, the gas
installation as well as the connect flue oulets are to be
checked every two years by an expert (this has to be
arranged by the person responsible).

SOME USEFUL HINTS

Make sure that:

The refrigerator is not operating on 12 V when the ve-
hicle is parked, otherwise you will drain the car battery in
a short time.

Defrosting is carried out periodically.

The refrigerator is left with the door(s) ajar when it is not
to be used for some time.

Liquids or items with a strong odour are well packaged.

The ventilation openings are unobstructed.

The door is secured by means of the travel catch when
the caravan is on the move.

Only one mode of operation at a time is used to run the
refrigerator.

GUARANTEE AND SERVICE

The refrigerator is guaranteed for one full year on condition
that it is used in a correct manner and in accordance with
these operating and installation instructions.

It is also embraced by a European guarantee as described
in the brochure supplied with the refrigerator.

Service and spare sparts are obtainable from your dealer or
Electrolux - consult the telephone directory

TECHNICAL DATA

RM 4180/ 81

Overall dimensions, refrigerator

Height

. . . . . . . . . . . . . . . . . . . . . . . .592 mm

Width

. . . . . . . . . . . . . . . . . . . . . . . .401 mm

Depth (incl. cooling unit)

without door. . . . . . . . . . . . .427 mm
with door. . . . . . . . . . . . . . . .461 mm

Build-in dimensions

Height

. . . . . . . . . . . . . . . . . . . . . . . .595 mm

Width

. . . . . . . . . . . . . . . . . . . . . . . .405 mm

Depth

. . . . . . . . . . . . . . . . . . . . . . . .440 mm

Capacity

gross

. . . . . . . . . . . . . . . . . . . . . . . . . 40

lit.

net

. . . . . . . . . . . . . . . . . . . . . . . . . 37

lit.

Weight (without packaging) . . . . . . . . . . . . . 18

kg

Electrical data

Input 230 V . . . . . . . . . . . . . . . . . . . . . 105 watt

12 V . . . . . . . . . . . . . . . . . . . . . 100 watt

Energy consumption /24 h. . . . . . . . .2,1 kWh

LP gas data

Input

. . . . . . . . . . . . . . . . . . . . . . . . 186 watt

ditto, low flame . . . . . . . . . . . . . . . . . . . .86 watt
Energy consumption /24 h. . . . . . . .0,24

kg

Cooling medium Ammonia (R 717)

INSTALLATION INSTRUCTIONS

REPOSITIONING THE HINGES

The door hinges can be moved to the opposite side in the
following way:

Unscrew the upper hinge pin, taking care not to lose the
set of washers and bushes.

Lift the door from the lower hinge pin.

Unscrew the pin and mount it on the opposite side hinge.

Unscrew the travel catch and mount it on the opposite
side.

On the upper edge of the door are two plastic inserts for
the alternative holes of the travel catch. Pry out carefully
and exchange

Fit the door on the pin and reassemble the pin with
washers and bushes in its new place.

Check that the door closes properly and seals all round.

DOOR PANEL

The door panel can easily be mounted or changed. The
dimensions of the panel must be:

Height ................................. 522 mm
Width ................................. 370 mm
Thickness .................... max 1,3 mm

Remove the door, see REPOSITIONING THE HINGES.

The sealed cooling system must not be opened, since

it is under high pressure.

10

Summary of Contents for RM 4180

Page 1: ...MANUAL CARAVAN 821 2674 01 DES TB 11 95 Typ C 40 110 RM 4180 RM 4181 0085AQ0716 ...

Page 2: ...later than seven days after the refrigerator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The right gas pressure is 30 mbar The right voltage is 230 volts The data plate contains e g the following details Model designation RM Product number Serial number Since these details will be needed if you have to contact service perso...

Page 3: ...flashing 8 Keep the D button pressed for a further 10 to 15 secon ds to active the flame failure device then release it If you have Model RM 4180 proceed as follows 3 Turn on the gas supply by pressing the D knob and turning it to the position 4 Set the thermostat knob E to the highest setting 5 Keeping the flame failure device buttom D pressed operate the igniter G until the flame lights 6 Keep t...

Page 4: ... ice The defrost water runs from a collector channel to a recep tacle at the rear of the refrigerator where it evaporates Defrost water in the freezer compartment should be mop ped up with a cloth When the ice has melted wipe the refrigerator dry and restart it Place the food items back inside but wait until the refrigerator is cold before making ice cubes CLEANING THE REFRIGERATOR Clean the insid...

Page 5: ...tion that it is used in a correct manner and in accordance with these operating and installation instructions It is also embraced by a European guarantee as described in the brochure supplied with the refrigerator Service and spare sparts are obtainable from your dealer or Electrolux consult the telephone directory TECHNICAL DATA RM 4180 81 Overall dimensions refrigerator Height 592 mm Width 401 m...

Page 6: ...on unit is ventilated via two openings in the wall of the caravan see fig 5 Fresh air enters through the lower opening and warm air is discharged through the upper one Locate the lower opening immediately above the floor of the recess and the upper one as high as possible above the condenser C of the refrigeration unit at least as shown in fig 6b but preferably as shown in fig 6a Ventilation grill...

Page 7: ...minal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured red In the United Kingdom the plug or circuit to the ref...

Page 8: ......

Page 9: ......

Page 10: ......

Reviews: