OPERATING INSTRUCTIONS

CONTROLS

The refrigerator can be run on either 230 V, 12 V or LP gas.
Changing between these modes of operation is carried out
by means of the controls of the control panel shown in fig 3.

Two rocker switches are used to select the electric power
supply, one for 230 V (B) and one for 12 V (A).

Refrigerator temperature is controlled by a thermostat (C)
when the unit runs on 230 V. The gas supply is turned
on/off by means of the knob (D). When lighting the gas, one
must press in the knob as explained further on.

Refrigerator temperature is controlled by a thermostat (E)
when the refrigerator runs on LP gas. Please note that the
thermostat has no "off'' position.

In model RM 4181, the gas flame is electronically lit, moni-
tored and relit if necessary. For this the toggle switch (F)
should be ``on'' during gas operation.

An indicator lamp in the switch flashes when the automatic
igniter attempts to light the burner. Otherwise this lamp is
off.

In model RM 4180 a manual piezo-eletric igniter is used.
When the button (G) is pressed, sparks are generated at
the burner.

Inside the refrigerator at bottom left is a sight glass for the
burner. A blue light can be seen through it when the flame
is alight. (RM 4180)

STARTING THE REFRIGERATOR

The position numbers refer to fig. 3.

LP Gas operation

After initial installation, servicing, or changing gas cylinders
etc., the gas pipes may contain some air which should be
allowed to escape by briefly turning on the refrigerator or
other appliances. This will ensure that the flame lights
immediately.

To start gas operation:

1. Open the shut-off valve of the gas bottle (check that there

is enough gas). Open any on-board shut-off valve.

2. Check that the switches for mains and 12 V operation are

off.

If you have Model RM 4181 proceed as follows:

3. Turn on the gas supply by pressing the (D) knob and

turning it to the position

4. Set the thermostat knob (E) to the highest setting.

5. Depress switch (F). A light in the switch should now start

to flash, indicating that sparks are being generated at the
burner.

6. Press the (D) button. This opens the flame failure device

and allows gas to flow to the burner.

7. When the flame lights, the sparking stops automatically

and the switch stops flashing.

8. Keep the (D) button pressed for a further 10 to 15 secon-

ds to active the flame failure device, then release it.

If you have Model RM 4180 proceed as follows:

3. Turn on the gas supply by pressing the (D) knob and

turning it to the position

4. Set the thermostat knob (E) to the highest setting.

5. Keeping the flame failure device buttom (D) pressed,

operate the igniter (G) until the flame lights.

6. Keep the (D) buttom pressed for a further 10 to 15 se-

conds then release it.

The flame can be observed in a wiewing glass inside the
refrigerator at the bottom left (RM4180).

To terminate gas operation, turn knob (D) to ``

'' and (when

applicable) set switch (F) to ``0''.

230 V Operation

Turn off gas or 12 V operation when applicable.

Turn the knob (C) of the thermostat to its highest (col-
dest) position.

Set switch (B) to position I. The switch will light up green
when the power supply is connected.

12 V Operation

Only operate your refrigerator on 12 V when the engine of
the vehicle is running - otherwise your battery will soon be
discharged.

If applicable, turn off the gas operation.

Set the 12 V rocker switch (A) to I. The switch will light
up red when the power supply is connected.

WINTER OPERATION

Please check that the ventilation grilles or the flue outlet are
not blocked by snow, leaves etc.

ELECTROLUX ventilation grilles A 1620 (fig 2), can be
fitted with winter covers, model WA 120, to protect the
cooling unit against cold air. The covers may be fitted when
the outside temperature is below approx. 10

°

C and should

be fitted when the temperature is below the freezing point.

We suggest that you fit the winter covers also in the case
that the vehicle is laid up during the winter months.

REGULATING THE TEMPERATURE

The position number refers to fig. 3.

It will take a few hours for the refrigerator to reach normal
operating temperature. So we suggest you start it well in
advance of a trip and if possible store it with precooled
foodstuffs.

On 230 V operation the refrigerator is controlled by a ther-
mostat and the thermostat knob (C) should be set at 3-5. If
a lower (colder) temperature is desired, set the thermostat
to a higher figure.

On 12 V operation the refrigerator works continuously.

On LP gas operation the refrigerator temperature is regula-
ted by the gas thermostat (E), which should be set at 3-5. If
a lower (colder) temperature is desired, set the thermostat
to a higher figure.

Caution!

Only use one source of energy at a time

8

Summary of Contents for RM 4180

Page 1: ...MANUAL CARAVAN 821 2674 01 DES TB 11 95 Typ C 40 110 RM 4180 RM 4181 0085AQ0716 ...

Page 2: ...later than seven days after the refrigerator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The right gas pressure is 30 mbar The right voltage is 230 volts The data plate contains e g the following details Model designation RM Product number Serial number Since these details will be needed if you have to contact service perso...

Page 3: ...flashing 8 Keep the D button pressed for a further 10 to 15 secon ds to active the flame failure device then release it If you have Model RM 4180 proceed as follows 3 Turn on the gas supply by pressing the D knob and turning it to the position 4 Set the thermostat knob E to the highest setting 5 Keeping the flame failure device buttom D pressed operate the igniter G until the flame lights 6 Keep t...

Page 4: ... ice The defrost water runs from a collector channel to a recep tacle at the rear of the refrigerator where it evaporates Defrost water in the freezer compartment should be mop ped up with a cloth When the ice has melted wipe the refrigerator dry and restart it Place the food items back inside but wait until the refrigerator is cold before making ice cubes CLEANING THE REFRIGERATOR Clean the insid...

Page 5: ...tion that it is used in a correct manner and in accordance with these operating and installation instructions It is also embraced by a European guarantee as described in the brochure supplied with the refrigerator Service and spare sparts are obtainable from your dealer or Electrolux consult the telephone directory TECHNICAL DATA RM 4180 81 Overall dimensions refrigerator Height 592 mm Width 401 m...

Page 6: ...on unit is ventilated via two openings in the wall of the caravan see fig 5 Fresh air enters through the lower opening and warm air is discharged through the upper one Locate the lower opening immediately above the floor of the recess and the upper one as high as possible above the condenser C of the refrigeration unit at least as shown in fig 6b but preferably as shown in fig 6a Ventilation grill...

Page 7: ...minal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured red In the United Kingdom the plug or circuit to the ref...

Page 8: ......

Page 9: ......

Page 10: ......