NOFROST UNDERCOUNTER FREEZERS WITH ELECTRONIC TIMER
14/20
7. COMPONENTS
7.1 CONTROL PANEL :
- ON/OFF led (GREEN)
A
;
- thermostat knob
B
;
- led SUPER (GIALLO)
C
;
- SUPER
D
button (pulse button with
timed exclusion about 50 hours);
in case of first switching on or
power failure the SUPER function
sets up automatically
(see paragraph 5.2);
- TEMPERATURE ALARM led (RED)
E
.
7.2 FREEZER COMPARTMENT :
- fan
D
(220V 50Hz – 1.6 W –
2000 rpm)
- couple of thermal overload cut-outs
E
- evaporator battery
F
- defrosting heater
G
( 151 W – 381
Ω
)
- conveyor
K
- fixing clips
L
OPERATION TEMPERATURE
TYPE OF THERMAL
OVERLOAD CUT-OUT
OPENING CLOSURE
DEFROSTING
+ 10 °C
- 1 °C
SAFETY
+ 40 °C
+ 30 °C