The most reasonable method is the time control
of power absorption by a metra tester (left) or a
current probe (right).
If the current increases abruptly, the high-
voltage part begins operating and microwave
energy is emitted.
The proportion of on/off switching times are to be taken from the technical documents:
Simplest rule:
50% on 50% off
50% capacity
30% on 70% off
30% capacity
Useful clock cycle:
30 seconds
1 liter water (17 -24°)
62 seconds full capacity
Measurement of capacity simple version
Important
- Use a container with thin
material. Thick
container walls extract
parts from the water of
the rising heat and
falsify the measuring
result.
- If possible, initial
temperature 20°C
- Exact time measurement
- An exact thermometer, if
possible a digital one
- Stir the water before the
measurement
Measurement of capacity levels
created by TSE-N, Reiner Kurzke
Page 20