background image

30" Combination Installation –

Built-In Microwave /Single Wall Oven/Warmer Drawer

High standards of quality at Electrolux Home Products, Inc. mean we are 

constantly working to improve our products. We reserve the right to change 

specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

250 Bobby Jones Expressway 

Augusta, GA 30907 

1-877-4electrolux (1-877-435-3287) 

electroluxicon.com

CANADA

5855 Terry Fox Way 

Mississauga, ON L5V 3E4 

1-800-265-8352 

electroluxicon.ca

MO_EW_WD INST  09/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.

30" Combination Installation Specifications

Always consult local and national electric codes. 

(Refer to product-specific electrical specifications on this page.)

Minimum 24" deep cutout dimension is critical for proper combination
installation, to ensure that each built-in product’s faceplate will fit
flush against cabinet front.

Bases must be level and cabinet front must be square.

Minimum 4-1/2" required distance from bottom of Warmer Drawer 
cutout to floor.

Respect critical dimensions as noted for proper installation of built-In
products.

Minimum 23-1/4" clearance needed for Wall Oven door depth 
when open.

30" Built-In Convection Microwave Specifications

Product Weight – 60 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.55 kW 
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)

Amps @ 120 Volts = 13 Amps

Consult local building code in the event that cutout opening may 
be required to be enclosed with sides, ceiling and rear partition.

Full base of solid plywood or similar material required, capable of
supporting 100 Lbs. 

Minimum 3-1/8" clearance required from bottom of Built-In Microwave
cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap
between both product faceplates.

30" Electric Single Wall Ovens Specifications

Product Weights – (E30EW75GPS) 178 Lbs. / (E30EW75GSS) 175 Lbs.

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 
AC only electrical supply with ground required on separate circuit 
fused on both sides of line.

Connected Load (kW Rating) @ 240 / 208 Volts = 4.0 / 3.0 kW

Amps @ 240 / 208 Volts = 16.6 / 14.4 Amps

To support Wall Oven, two 3"-wide x 3/4" thick planks must be installed
as a base, capable of supporting 200 Lbs. Do NOT use full base, since
planks are necessary to allow for proper air displacement.

30" Warmer Drawers Specifications

Product Weights – (E30WD75GPS / E30WD75GSS) 49 Lbs. /
(E30WD75GTT) 41 Lbs.

Voltage Rating – 120V / 450W / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.45 kW 
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)

Amps @ 120V =  3.75 Amps

Full base of solid plywood or similar material required, capable of
supporting 100 Lbs. 

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxicon.com for detailed instructions.

 24" min.

3" max.

††

 30" min.

9

7

/

8

" min.

10

1

/

4

" max.

1

3

/

4

" min.

26

1

/

2

" min.

27" max.

Full plywood base
required to support
100 lbs.

Full plywood base
required to support
100 lbs.

28

1

/

2

" min.

28

7

/

8

" max.

28

1

/

2

" min.

28

3

/

4

" max.

Two 3" wide
by 

3

/

4

" thick

planks must be
installed, capable
of supporting
200 lbs.

30" Warmer
Drawer Cutout

For models:
E30WD75GPS
E30WD75GSS
E30WD75GTT

4"x 4" opening to route
armored cable

28

1

/

2

" min.

28

3

/

4

" max.

5"

11

1

/

2

"

120V/60 Hz
grounded electrical
outlet should NOT
be located within
shaded area

4

1

/

2

" min.

required

19

7

/

8

" min.

20

3

/

8

" max.

   24" min.**

 (critical

  dimension)

Electrical junction
box location

Bottom of

oven cutout

11

5

/

8

" min.**

(critical

dimension)

For detailed product dimensions
and installation specifications, refer
to model-specific product page and
installation guide on web

 * Minimum 3

1

/

8

"

clearance required
from bottom of
Built-In Microwave
cutout to top edge of
Wall Oven’s faceplate,
leaving a 2" visible
gap between both
product faceplates

** Critical dimension –

MUST be applied

 †

Maximum height

depends on critical
dimension (11

5

/

8

")

††

Electrical junction

box for Wall Oven
must be lower than
the Warmer Drawer
cutout

2"

(visible

 gap)*

30" Electric Single
Wall Oven Cutout

For models:
E30EW75GPS
E30EW75GSS

30" Built-In
Microwave Cutout

For model:
E30MO65GSS

Summary of Contents for Icon E30WD75GSS

Page 1: ... wire service with a separate ground wire Appliance must be grounded for safe operation NOTE Always consult local and national electric codes Refer to Product Installation Guide for detailed installation instructions on the web at electroluxicon com Specifications subject to change 1 6 Cu Ft Yes Yes Yes Yes 450 Yes Yes Yes Yes Optional 6 1 2 20 15 16 19 1 4 11 1 4 30 23 3 8 44 1 8 80 F 210 F Right...

Page 2: ...n Microwave and or Electric Single Wall Oven Refer to model specific Combination Installation Specifications pages on web Optional Accessories ServeWare PN 5304447729 Warmer Drawer Wall Oven Combination Specifications To support Wall Oven when using in combination with Warmer Drawer two 3 wide x 3 4 thick planks must be installed as a base capable of supporting 200 Lbs Do NOT use full base since p...

Page 3: ...red on separate circuit fused on both sides of line Connected Load kW Rating 240 208 Volts 4 0 3 0kW Amps 240 208 Volts 16 6 14 4 Amps To support Wall Oven two 3 wide x 3 4 thick planks must be installed as a base capable of supporting 200 Lbs Do NOT use full base since planks are necessary to allow for proper air displacement 30 Warmer Drawers Specifications Product Weights E30WD75GPS E30WD75GSS ...

Page 4: ... 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line Connected Load kW Rating 240 208 Volts 4 0 3 0kW Amps 240 208 Volts 16 6 14 4 Amps To support Wall Oven two 3 wide x 3 4 thick planks must be installed as a base capable of supporting 200 Lbs Do NOT use full base since planks are necessary to allow for proper air displac...

Page 5: ... Load kW Rating 240 208 Volts 4 0 3 0kW Amps 240 208 Volts 16 6 14 4 Amps To support Wall Oven two 3 wide x 3 4 thick planks must be installed as a base capable of supporting 200 Lbs Do NOT use full base since planks are necessary to allow for proper air displacement 30 Warmer Drawers Specifications Product Weights E30WD75GPS E30WD75GSS 49 Lbs E30WD75GTT 41 Lbs Voltage Rating 120V 450W 60Hz 15 Amp...

Reviews: