0409
5
2
01103040
Page
Notice
Date
OPERATING
HANDBOOK
5. Operating incidents
The heating does not
work, or works badly
Check the temperature preselection.
Check the safety thermostat.
Check to see if the panel is showing
overheating or a high temperature.
Gas heating
Check the gas inlet.
Clean pressure reducer fi lters.
Check electronic ignition.
Check the position of the ignition
electrodes and fl ame control.
Check operation of the gas solenoid
valve.
The fl ame is yellow
Check that the vapour intake fan is
working and is turning in the right
direction.
Check that air inlets are not blocked.
Check the combustion products
exhaust fl ue.
Check injector calibration.
Clean machine air inlet fi lters.
Check the cylinder’s rotation
detection system.
Check the panel’s sensors.
Encountered problem
Cause of problem
Solution