- 10 -
TSE-N 05.00 A. B.
599 50 78 52EN
7. Test Routine Computer
Application:
This test routine was developed for the test stand in the factory and can
also be used in the field (advantageously together with a transparent
door). All electrical components in the appliance are selected.
Start:
switch off the main switch
close the door
For the following controls, these key combinations are valid:
press and keep pressed
2 keys / no. 153 0259-08/2: program selection (LEDs
ECO
and
INTENSIVE
)
5 keys / no. 153 0259-05/8:
ECO
and
INTENSIVE
8 keys / no. 153 0259-09/0:
HALF LOAD
and
SHORT
together
switch on the main switch
keep the key(s) pressed for at least 5 sec (corresponding LEDs flashing during
this time)
The display shows the lower circle of digit 8 and/or the corresponding LEDs will
flash permanently
Stop (main switch):
If the program is stopped by the main switch it is possible to select a wash pro-
gram immediately after switching on again.
If the test routine is started anew after this stop as described under start the
cycle goes directly into step 9 and first pumps the water from the tub
(corresponding LED flashing at the end).
Now the test routine can be started anew as described under start.
Sequence:
See enclosed flowchart.