background image

6

4.

 

Check the Gas Control Taps for ease of operation.

5.

 

Check and clean the Main Burner Injectors, and remove
all foreign matter around the openings into the Main
Burners.

6.

 

Light, and check the Pilot Burner, the operation of the
Thermocouple, and the lighting of the Main Burners.

7.

 

Check the Main Burner Plaques to ensure that there is
even burning and no light-back, and no cracks in the
ceramic plaques.

REPLACEMENT OF PARTS & SERVICING

The servicing of this appliance must be carrier out a
competent person who has CITB Certification, and who is
CORGI Registered. All work must comply with the Gas
Safety Regulations.

BEFORE DISMANTLING ANY GAS-CARRYNG
PARTS, TURN OFF THE GAS SUPPLY AT THE
ISOLATING TAP.

It is recommended that the servicing of this appliance should
be carried out under a service contract provided by Electrolux

Commercial Service (ECS). Benefits of a service contract
include regular visits from trained engineers, priority
breakdown treatment and extensive spare parts back up

service. A service contract is available to cover ALL your
equipment and work carried out is guaranteed. For details
contact Electrolux Commercial Service: 0345-364364.

SPARE PARTS
Only genuine 

Electrolux

 spares should be used on this

appliance and can be obtained from:

Electrolux Foodservice Equipment
Crystal Court Aston Cross,
Business Park Aston Birminghan
B6 5RQ    U.K.

              telephone: 0121 – 220 2852/3

telefax: 0121 - 2202850

When ordering spare parts please quote the serial number and
the model number of the appliance together with the part
number of the component required.

SYMPTON
Smell of gas
Pilot Burner does not light using
Piezo Ignitor

Pilot Burner does not light using
ignition OR taper
Pilot Burner goes out following ignitor

Main Burner flames uneven
lifting off, burning erratically

Pilot estabilishes and Main Burner ignites but
Pilot and Main Burner go out after several
minutes

FAULT FINDING

POSSIBLE CAUSE
a)   Gas leak
a)

 

No gas to appliance

b)

 

No spark at Ignition Electrode

c)

 

Ignition Cable damaged

d)

 

Faulty Ignition Electrode (cracked ceramic)

e)

 

Ignition Unit (loose fitting, no earth)

f)

 

Faulty Igniter

a)    Blocked Pilot Injector

a)

 

Thermocouple tip out of position

 

b)

 

Thermocouple loose at Gas Control Tap

 

 

c)

 

Thermocouple damage (tip burned)

d)    Faulty Gas Control Tap
a)

 

Dirt blocking Burner Inlet

b)

 

Blocked Injector

c)

 

Wrong gas pressure

d)

 

Wrong Injector fitted for gas type

e)

 

Ceramic Plaque on Main Burner
cracked or broken

f)

 

Thermocouple Tip not securely held in Pilot
Burner

REMEDY
a)   Locate leak and make joint sound
a)

 

Turn on gas at Isolating Tap

b)

 

Remake lead connections

c)

 

Replace Ignition Cable

d)

 

Replace Electrode

e)

 

Tighten locknut on Igniter

f)    Replace Igniter
a)

 

Clean or replace Pilot Injector

a)

 

Check Pilot Burner for damage replace if
necessary

b)

 

Clean end of Thermocouple at Tap tighen
Thermocouple Nut - finger tight, then a
further ½ turn with a spanner.

c)

 

Replace the Thermocouple

d)    Replace Tap
a)

 

Clean

b)

 

Clean or fit new Injector

c)

 

Check and adjust pressure

d)

 

Check gas type and fit correct Injectors

e)

 

Replace Main Burner

a)

 

Reposition and tighten the Thermocouple
in Pilot Burner

A. OUTER TOP PANEL

REMOVE/REPLACE (figure 3)

1.

 

Pull the outer top panel forward (1) and lift clear to
release keyhole slots from the locating pegs on the side
panels then lift clear of the appliance.

2.

 

Replace in a reverse sequence ensuring that there is no
gap between the top of side panels and the outer top
panel..

B. INNER LINER

REMOVE/REPLACE (figure 3)

1.

 

Complete procedure A.

2.

 

Lift the inner liner (2) clear of the appliance.

Summary of Contents for G580

Page 1: ...200100222 ISSUE 02 01 GAS SUPERGRILL JET GRILL USER S INSTALLATION AND SERVICING MANUAL Zanussi Professional PNC 283581 283580 Model GSG 580 JG G580 Electrolux Foodservice ...

Page 2: ...G 900 NG 20 mbar 8 wg BURNER RATING MODEL TYPE OF GAS PRESSURE 900 Natural Gas 6 2kW 21 000Btu h 900 Butane Propane 6 2kW 21 000Btu h TOTAL RATING MODEL TYPE OF GAS RATING 900 Natural Gas 12 4kW 42 000Btu h 900 Butane Propane 12 4kW 42 000Btu h SAFETY NOTES 1 It is the law that all gas appliances are installed by competent person in accordance with the requirements of the Gas Safety Installation a...

Page 3: ...e appliance is to stand is level and is capable of supporting the weight of the appliance If the support or surround is made of a combustible material it is recommended that they shall be clad by a suitable non combustible heat insulating material and that the local fire regulations are observed 3 IMPORTANT It is necessary to ensure an adequate supply of fresh air to appliance for combustion and v...

Page 4: ...re holding the Main Control Knob pressed in for a longer period NOTE The Pilot Burner can also be lit by applying a lit spell or taper to the Pilot Burner whilst operating the Main Control Tap as directed above TO OPERATE THE REAR BURNER Once the pilot been established the Rear Burner can be turned on Turn the Main Control Knob anti clockwise to the LOW position Rear Burner will automatically igni...

Page 5: ...uld not be used as they attack the metal especially the aluminium Brander Plate When cleaning the interior of the grilling compartment care must be taken to avoid damaging the ceramic plaques of the burners Any deposits left on plaques will quickly burn off by themselves Grills that are used continuously for cooking meat products and where extensive use is made of basting are likely to became thic...

Page 6: ...ght using ignition OR taper Pilot Burner goes out following ignitor Main Burner flames uneven lifting off burning erratically Pilot estabilishes and Main Burner ignites but Pilot and Main Burner go out after several minutes FAULT FINDING POSSIBLE CAUSE a Gas leak a No gas to appliance b No spark at Ignition Electrode c Ignition Cable damaged d Faulty Ignition Electrode cracked ceramic e Ignition U...

Page 7: ... Dept F GAS TAPS REMOVE REPLACE figure 2 1 Complete procedure C 2 Disconnect the gas supply pipe 8 pilot outlet 9 and main gas outlet 10 3 Disconnect thermocouple 11 4 Remove gas tap from the appliance 5 Check gas flow indication arrow on the replacement tap and fit in a reverse sequence ensuring that all gas connections are sound Ensure the Bypass Orifice 7 is not removed from the outlet tee when...

Page 8: ...nut 4 and ease tube 5 away from burner NOTE the injector 6 is secured within the tube of the pilot burner and may have to be extracted by carefully prising around its edge 4 Carefully clean replace the injector using soft fine wire 5 Reassemble by reversing the above procedure L PILOT BURNER REMOVE REPLACE figure 4 1 Follow procedure C 2 Unscrew two screws 9 and remove the pilot protection bracket...

Page 9: ...Burners are ignited by the pilot burner M MAIN BURNER REMOVE REPLACE figure 5 1 Follow procedure B 2 Disconnect gas supply at burner injector unit 1 3 Remove two screws 2 and lift main burner away from appliance N MAIN BURNER INJECTOR REMOVE REPLACE figure 5 1 Follow procedure M 2 Unfasten three screws 3 and remove aeration cover 4 complete with injector holder 6 3 Unscrew injector 5 clean or rene...

Page 10: ...487 2000 21411 2100 51480 4300 51480 4300 12250 8300 12250 8200 21786 4134 12250 8400 12250 8700 12250 4900 12250 7600 12250 5000 12250 5000 12250 4800 12250 5200 18900 5900 12250 5400 21852 2005 20600 2105 21702 2165 ...

Page 11: ...G 181 SXJ 222 21538 3500 21415 9801 21720 2105 51480 5601 12250 6700 1224 7100 55000 2300 54881 5801 24280 3900 SBF 166 SBX 263 55000 2100 55000 2000 55000 2200 55000 0400 54883 7301 SEW 848 55000 0800 SXX 148 SEW 577 55000 1600 55000 1000 55000 3300 55000 3200 32000 0000 SGC 584 1224 7066 55000 1200 55000 0600 55000 0900 55000 2700 32000 0200 32000 0300 21704 3125 1224 7060 55000 1300 21403 3000 ...

Page 12: ... 215383300 CONDUCCION BYPASS BYPASS PIPE 1 550003200 CONDUCCION VALVULA QUEMADOR VALVE MAIN BURNER PIPE 1 215383500 CONDUCCION GRIFO VALVULA GAS TAP VALVE PIPE 1 550003300 CONDUCCION GRIFO QUEMADOR GAS TAP BURNER PIPE 1 550003400 CONDUCCION PILOTO PILOT BURNER PIPE 1 248203900 EMPUÑADURA ESP ELESA L 90 M 8 PLASTIC HANDLE 4 438310600 CONJ CABLE SILICONA PARA PIEZO PIEZO IGNITER SILICON CABLE 1 5148...

Page 13: ...0 GLP INJECTOR MAIN BURNER LPG D 1 20 1 514805300 OBTURADOR D 1 6 BYPASS ORIFICE LPG 1 514805100 OBTURADOR D 2 50 BYPASS ORIFICE NG 1 SXJ227 TUERCA R 1 4 D 8 2 LATON NUT R 1 4 2 217043125 TORNILLO FIJACIÓN FIXING SCREW 2 SXX148 MUELLE MANDO KNOB SPRING CLIP 2 Parts marked together with an appropriate Data Plate form the kit for converting the appliance to burn an alternative gas The 3 8 Governor i...

Reviews: