Electrolux FROST FREE CHEST FREEZER Service Manual Download Page 6

Service manual  

COLD 

5. OPERATION 

 
5.1 NORMAL 

 
When the thermostat knob is on (OFF) position it means that: 

 

the compressor is off; 

 

all Leds are off; 

 

the electronic board is powered ( 220-240V 50Hz ! ! ! ). 

 
Warning: the electronic board is powered with a 220-240V 50Hz voltage even if the thermostat 
knob is on (OFF) position. Therefore, disconnect the appliance from the electric power before 
operating with the electronic board. 

 
By rotating clockwise the thermostat knob the green LED switches ON. 
 
In FROST-FREE chest freezer, the humidity inside the freezer compartments accumulates on the 
evaporator battery, thanks to the air circulation, thus preventing the formation of frost on food. 
During normal operation time the electronic board powers the compressor and the fan circuits. 
The operation time which corresponds to the interval between the following defrosting lasts about 14 hours 
with normal opening of the door ( it can last up to 71 hours if the door is never opened !). 
 

5.2 NORMAL OPERATION WITH FIRST SWITCHING ON OR POWER FAILURE 

 
In case of fault when the appliance is switched on for the first time or in case of a power failure, one of the 
two conditions described below occurs: 
 
1. If the internal temperature is higher or the same as the cut-in temperature of the thermostat (CUT-IN), 
when the power is restored, the electronic board activates the compressor and the fan till the set 
temperature is reached and after 5 hours the electronic board activates the defrosting procedure. 
 
2. If the internal temperature is lower than the cut-in temperature of the thermostat (CUT-IN), when the 
power is restored, the compressor functions in thermostatic conditions and after 5 hours the electronic 
board starts the defrosting procedure. 
 
The electronic board activates, anyway, 

the defrosting procedure after 5 hours in case of both the first 

switching on and a power failure

 
Warning

: if you turn the thermostat knob anti-clockwise till the zero position (OFF), all the counters will be 

reset (apart from those necessary to the manual defrosting procedure) and once the thermostat knob has 
been turned clockwise in ON position, the compressor will operate in thermostatic conditions. 

 
5.3 DEFROSTING 

 
All the humidity in the compartment accumulates on the evaporator, which is the coldest part of the 
compartment; periodically. Every about 14 hours minimum with normal door openings (till 71 hours if the 
door is never opened!), it is necessary to defrost the ice which forms on the battery. Therefore the 
electronic board disconnects the circuit that powers the compressor and the fan and, after checking for the 
defrosting heater, it powers the defrosting heater for about 20 minutes minimum. 

In case the defrosting 

heater is interrupted or its connector is disconnected, green and yellow LEDs flashing alternately 
and the defrosting heater lasts 1 hour. 

 
The heat generated by the defrosting heater does not affect the temperature of the freezer compartment or 
the temperature of the food packages, since the whole thermal energy is consumed in the defrosting 
process of the ice on the evaporator. 
 
After 20 minutes, the board detects every minute the signal of the defrosting process in order to determine 
the intervention of the defrosting cut-out switch. 
When the defrosting cut-out switch intervenes, the electronic control switches on the compressor and the 
fan again with a 5 minute delay. 
 
If for any reason, the defrosting cut-out switch does not intervene and the temperature of the battery rises 
up to +40 °C, the defrosting heater will be switched off by the safety thermal switch. 
FROST FREE CHEST FREEZER with ERF1050 

electronic 

 

    6/16 

 

Summary of Contents for FROST FREE CHEST FREEZER

Page 1: ... Customer Care and Service Budapest Erzsébet királyné útja 87 HUNGARY H 1142 06 01 2005 Fax 36 1 221 9866 FROST FREE CHEST FREEZER With ERF1050 electronic Publication no 599 371 214 LA HUE FROST FREE CHEST FREEZER with ERF1050 electronic 1 16 ...

Page 2: ...EZING 8 5 5 NTC SENSOR MALFUNCTIONING 8 6 COMPONENTS 9 6 1 CONTROL PANEL 9 6 2 FREEZER COMPARTMENT 9 6 3 DEFROST HEATER 10 6 4 OVERLOAD CUT OUT 10 6 5 LID LIGHT SWITCH 10 6 6 ELECTRONIC BOARD ERF1050 11 7 INDICATOR LIGHT MEANINGS AND FAULT CODES 12 8 MANUAL DEFROSTING PROCEDURE 12 8 1 FORCED DEFROSTING TIME SHEDULE 13 9 ACCESSABILITY COLD MODULE 14 10 ACCESSABILITY LID 15 11 ACCESSABILITY LAMP SWI...

Page 3: ...REE CHEST FREEZER models WITH ELECTRONIC TIMER ERF1050 2 WORKING IDEA AIR DISRITBUTION A fan near battery type evaporator moves the air in the freezer area The cold air gets to the air channels of the lid and distributes via its holes to all storing area Air channel in the lid fan evaporator SUCTION The return airflow is through a vent in the cabinet s false floor left hand side and up to the base...

Page 4: ...Service manual COLD 3 REFRIGERATION CIRCUIT Key 1 compressor 2 condenser 3 filter 4 capillary 5 heat exchanger 6 battery evaporator FROST FREE CHEST FREEZER with ERF1050 electronic 4 16 ...

Page 5: ...ector 9 defrosting heater 13 lamp 15 light switch 24 battery fan 26 safety thermal switch 40 C 27 defrosting cut out switch 10 C 28 running capacitor only for the models which feature it 41 electronic thermostat assembly with timer 56 NTC sensor FROST FREE CHEST FREEZER with ERF1050 electronic 5 16 ...

Page 6: ...ing procedure The electronic board activates anyway the defrosting procedure after 5 hours in case of both the first switching on and a power failure Warning if you turn the thermostat knob anti clockwise till the zero position OFF all the counters will be reset apart from those necessary to the manual defrosting procedure and once the thermostat knob has been turned clockwise in ON position the c...

Page 7: ...r if 1 hour after the defrosting start the safety thermal switches did not switch off the electronic board switches off anyway the defrosting heater and the process carries on FROST FREE CHEST FREEZER with ERF1050 electronic 7 16 ...

Page 8: ...compressor functions in thermostatic conditions The defrosting can occur with the SUPER function on 5 5 NTC SENSOR MALFUNCTIONING Fault alarm Flashing red light and static green light illuminated If during the normal functioning a NTC sensor failure occurs the signal coming from the sensor is out of range then The appliance functions with a predefined cycle by which the compressor is powered for 3...

Page 9: ...ervice manual COLD 6 COMPONENTS 6 1 CONTROL PANEL 6 2 FREEZER COMPARTMENT Evaporator battery Defrosting heater Couple of thermal overload cut out Fan FROST FREE CHEST FREEZER with ERF1050 electronic 9 16 ...

Page 10: ...lose when the lid is opened to an angle greater than 45º This activates the following functions via the electronic control board Interior lamp ON Air circulation fan OFF Lid open alarm after being open for 90 seconds Lid open activity is memorised by the electronic control system to determine the defrost cycle NOTE Because the evaporator is in the freezer area and the refrigerant is R600a the lamp...

Page 11: ...ard powering and compressor control J2 connector power fan components defrosting heaters and lamp J6 connector NTC sensor J7 connector lamp switch J1 1 neutral 2 line 3 free 4 compressor J2 1 fan 2 defrosting heaters 3 neutral 4 lamp 5 lamp J6 1 NTC 2 NTC J7 1 free 2 free 3 lamp switch 4 lamp switch Note the numbering there is in the connectors FROST FREE CHEST FREEZER with ERF1050 electronic 11 1...

Page 12: ...ures this is to avoid the possible opening of the thermal protector of the defrosting heater To start the manual procedure ensure that the electronic board is powered with thermostat knob ON position 5 or anyway in a position between 90 and 270 the lid closed lamp switch is OFF Perform the 3 following operations 1 turn the thermostat knob to OFF position 2 open the lid more than 45 o angle 4 times...

Page 13: ...TING TIME SHEDULE Available time Thermostat knob position Lid position Defrosting heater Green LED Yellow LED Key T 15 seconds t 5 seconds to check thermal protections F standard function FROST FREE CHEST FREEZER with ERF1050 electronic 13 ...

Page 14: ... fixing clip 3 Take away the bottom air channel 4 Pull out the corner air channel fixing pin 5 Cut in the foil on the evaporator cover 6 Click out the fan cover with a screwdriver 7 Remove the corner air channel 8 Take away the evap cover fixing screws FROST FREE CHEST FREEZER with ERF1050 electronic 14 ...

Page 15: ... without air inlet and outlets and ice cube maker holder In case of lid changing they have been transferred from old to the new one 1 Remove the closing part 2 Take away the air inlet 3 Take away the air outlets 4 Remove the ice cube maker holders Now you can put them in to the service door in opposite order FROST FREE CHEST FREEZER with ERF1050 electronic 15 ...

Page 16: ...ce manual COLD 11 ACCESSABILITY LAMP SWITCH 1 Remove the lamp screen 2 Screw out the lamp housing screws Lamp switch 3 Now you can take out the lamp switch FROST FREE CHEST FREEZER with ERF1050 electronic 16 ...