![Electrolux FROST FREE CHEST FREEZER Service Manual Download Page 10](http://html.mh-extra.com/html/electrolux/frost-free-chest-freezer/frost-free-chest-freezer_service-manual_94078010.webp)
Service manual
COLD
6.3 DEFROST HEATER
-Both side of evaporator,
-Water outlet channel heating, too
P=193W
R=275 Ohm
I= cca. 0,8A
6.4 OVERLOAD CUT-OUT
Defrosting switch off: with blue wires
Safety:
with white wires
N.B: changeable only together!
6.5 LID LIGHT SWITCH
This is a separate pendulum switch mounted next to the interior light in the lid. The switch contacts close
when the lid is opened to an angle greater than 45º. This activates the following functions via the electronic
control board:
• Interior lamp ‘ON’
• Air circulation fan ‘OFF’
• Lid open alarm (after being open for 90 seconds)
• Lid open activity is memorised by the electronic control system to determine the defrost cycle.
NOTE:
Because the evaporator is in the freezer area, and the refrigerant is R600a, the lamp holder and
the switch
must be EXPLOSION SAFE version!
Lamp holder
(explosion safe)
Bulb
E14 15W
Lamp switch
FROST FREE CHEST FREEZER with ERF1050
electronic
10/16