14
Replace Door Springs and Hinges
1.
Disconnect dishwasher from electrical supply.
2.
Remove outer door panel. (see Door Panel
Removal)
3.
Remove access panel. (see Remove Access Panel)
4.
Remove door spring hook from hole in frame, spring
from hinge and spring pad from hinge. Slide cover
off hinge and save for reuse.
5.
Open door to loosen screws that mount hinge to
inner door panel. Reclose door. Do not remove
screws until door is closed.
6.
Remove nuts from hinge mounting screws. Remove
screws. Slide hinge over to remove pin from frame
mounting hole.
7.
Install new hinge to complete repair.
NOTE
:
Springs and hinges can be changed
without pulling dishwasher from under counter
Hinge Cover
Spring Pad
Replace Motor Starting Relay
1.
Disconnect dishwasher from electrical supply.
2.
Remove access panel. (see Remove Access Panel)
3.
Remove wires from relay.
4.
Remove screw holding relay to front frame.
Replace Upper Rack
1.
Remove end cap from both rack slides.
2.
Pull rack forward off slides.
3.
Install new rack to complete repair.
Replace Upper Rack Tub Rollers
1.
See Upper Rack replacement.
2.
Remove back slide end cap slide rail off rollers
3.
Remove roller.
4.
When installing new roller, first turn screw
counterclockwise to keep from cross-threading hole,
then tighten roller.
5.
Install new relay. Reverse procedure to complete
repair.
6.
Start dishwasher motor to check operation.
Disassembly of Pump and Motor
The pump and motor are serviceable and are not
available as one unit. Servicing the water distribution of
this product can be done without removing the pump
from the dishwasher.
To Remove Motor and Pump from
dishwasher
1.
Disconnect dishwasher from electrical supply.
2.
Remove access panel. (see Remove Access Panel)
3.
Remove lower rack.
4.
Remove drain hose.
5.
Disconnect wire plug from motor.
6.
Turn three sump retainers into sump and loosen
sump.
7.
Push sump into tub from under dishwasher.
8.
Remove from inside of tub.
Pictured is the motor and wash pump removed from
the dishwasher. This is not an assembly and can be
disassembled for service.
Summary of Contents for FDR251RJR0
Page 20: ...A 3 DOOR For Model s FDR251RJR0 FDR251RJS0 FDS251RJR0 ...
Page 21: ...A 4 DOOR For Model s FDR252RBB0 FDR252RBS0 ...
Page 22: ...A 5 DOOR For Model s FDS252RBS0 ...
Page 23: ...A 6 TUB For Model s FDR251RJR0 FDR251RJS0 ...
Page 24: ...A 7 TUB For Model s FDS251RJR0 ...
Page 25: ...A 8 TUB For Model s FDR252RBB0 FDR252RBS0 ...
Page 26: ...A 9 TUB For Model s FDS252RBS0 ...
Page 27: ...A 10 MOTOR PUMP For Model s FDR251RJR0 FDR251RJS0 FDS251RJR0 FDR252RBB0 FDR252RBS0 FDS252RBS0 ...
Page 28: ...A 11 FRAME For Model s FDR251RJR0 FDR251RJS0 ...
Page 29: ...A 12 FRAME For Model s FDS251RJR0 ...
Page 30: ...A 13 FRAME For Model s FDR252RBB0 FDR252RBS0 ...
Page 31: ...A 14 FRAME For Model s FDS252RBS0 ...
Page 32: ...A 15 RACK For Model s FDR251RJR0 FDR251RJS0 FDS251RJR0 FDR252RBB0 FDR252RBS0 FDS252RBS0 ...
Page 35: ...B 3 ...