To select the wiring terminal position
5.3
Electrical wiring connection
Connect the mains water supply to the
water inlet by using a 15MM pushfit(not
supplied). DO NOT use excessive force
when making the connection.
NOTE:
Make sure the o-ring is clean and
on the correct position when putting the
terminal block on.
A proper sealant should always be used
to seal around the incoming pipework to
prevent water entering the wall.
It is essential that all pipe work is flushed
through to remove debris and swarf that
could otherwise damage the unit.
If entry is from the back, the nut of the
compression fitting will be partially behind
the surface of the wall. This area MUST
be left clear when plastering and tiling
around the pipework in order to make the
nut accessible for future adjustments(Fig. 5).
Turn on the mains water supply and check
for leaks in the pipework connection to the
shower.
NOTE:
At this stage no water can flow
through the unit.
To check the water supply leak
NOTE:
21mm
Fig. 5
14 www.electrolux.com
This Electrolux shower heater has 2 wiring
terminals and 2 earthing terminals shown
as Fig. 6. You can choose the proper
terminals when connecting the wiring.
Fig. 6
Wiring
terminal.
Earthing terminal
Route the cable into the shower unit for
connection to the terminal block as follows:
To do the wiring connection
Warning
Earth:
cable to terminal marked
Live:
cable to terminal marked
Neutral:
cable to terminal marked
Important!
When connecting the cable fully tighten the
terminal block screws and make sure that
no cable insulation is trapped under the
screws. Loose connections can result in
cable overheating.
only one of the terminal blocks is to used
for the supply cable connection, the other
terminal block is not to be used.
To connect the mains water supply