Technical Support - DMM
53/106
599 77 23-65 Rev. 03
13.5 Heating element
When replacing the heating element, please refer to the code shown in the list of
spare parts relating to the appliance.
It is strictly forbidden to tamper with the heating element in
any way!!!
(e.g. replace the NTC probe, etc...)
13.5.1 General characteristics
1. NTC probe
2. Heating element
The heating element of the washing water is armoured, i.e. it is inserted in sealed tubular stainless steel casing.
It is powered by two relays (K1, K2) situated in the circuit board. It is fitted with two thermal fuses which trip
if the temperature of the heating element exceeds the values for which they were calibrated.
(In the event of a fault an alarm will be displayed - see table of alarms).
1. Main electronic circuit board
11. Heating element
1
2